2015
DOI: 10.1021/acs.analchem.5b01566
|View full text |Cite
|
Sign up to set email alerts
|

Surface-Enhanced Raman Spectroscopy-Based Approach for Ultrasensitive and Selective Detection of Hydrazine

Abstract: A probe mediated SERS-based strategy is developed to selectively detect hydrazine with superb sensitivity. Ortho-phthaldialdehyde, a simple probe, reacts specifically with hydrazine to form phthalazine, a molecule that possesses a larger Raman cross section and better affinity toward the SERS substrate. We observed a limit of detection of 8.5 × 10(-11) M. Our method shows both qualitative and quantitative measurement of hydrazine with high sensitivity, low cost, and fast analysis time.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

3
55
0

Year Published

2015
2015
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 136 publications
(58 citation statements)
references
References 30 publications
3
55
0
Order By: Relevance
“…22 These analytical methods typically require 4 sample preparation steps that are not amenable to intracellular detection. For in vivo analysis, fluorescent probes that enable sensitive and noninvasive detection of N 2 H 4 become absolutely necessary tools.…”
Section: Introductionmentioning
confidence: 99%
“…22 These analytical methods typically require 4 sample preparation steps that are not amenable to intracellular detection. For in vivo analysis, fluorescent probes that enable sensitive and noninvasive detection of N 2 H 4 become absolutely necessary tools.…”
Section: Introductionmentioning
confidence: 99%
“…8 Thus, the N2H4 content in water is strictly limited by almost all countries, such as it is restricted to ≤0.02 mg/L in drinking water by the Chinese government. 9 To date, there are several analytical methods for hydrazine detection, such as SERS, 10 electrochemical methods, 11,12 titration, 13 gas chromatography, 14 ultraviolet spectrometry, 15 and HPLC. 16 A simple and rapid method for hydrazine detection is still urgently needed.…”
Section: Introductionmentioning
confidence: 99%
“…Some classic methods have been utilized for hydrazine detection. [6][7][8][9][10][11][12][13] However, these methods have disadvantages, such as complex operation and being time consuming. Comparatively, fluorescence spectroscopy has the advantages of high sensitivity and simple operation.…”
Section: Introductionmentioning
confidence: 99%