2018
DOI: 10.14716/ijtech.v9i1.1506
|View full text |Cite
|
Sign up to set email alerts
|

Surface Crack Detection with Low-cost Photoacoustic Imaging System

Abstract: Photoacoustic measurement in an imaging system is a unique method as it uses optical disturbance but observes its effect acoustically. Acoustical observation increases the quality of a measurement by reducing the scattering effect that often occurs in optical research. However, a few problems, such as cost and complexity, hinder development of a photoacoustic system. This report presents a design of a photoacoustic system using a laser diode and a commercial microphone as the acoustic emission source and senso… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
8
2

Relationship

2
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 17 publications
0
4
0
1
Order By: Relevance
“…Variations in measurements may be caused by nonuniform light fluence on the surface [ 31 ], and surface roughness of the sample [ 32 ]. The boundary line of the phantom intersection experiences repetitive reflection toward a very thin slit, which results in an increase in absorption as a result of repeated laser-material interactions [ 33 ] and shows up as an increase in the gray value of the pixel plot profile (Fig 7(c), and 7(d)). However, the photoacoustic technique still presents the difference in mechanical resonance for the different phantom stiffnesses tested.…”
Section: Discussionmentioning
confidence: 99%
“…Variations in measurements may be caused by nonuniform light fluence on the surface [ 31 ], and surface roughness of the sample [ 32 ]. The boundary line of the phantom intersection experiences repetitive reflection toward a very thin slit, which results in an increase in absorption as a result of repeated laser-material interactions [ 33 ] and shows up as an increase in the gray value of the pixel plot profile (Fig 7(c), and 7(d)). However, the photoacoustic technique still presents the difference in mechanical resonance for the different phantom stiffnesses tested.…”
Section: Discussionmentioning
confidence: 99%
“…Compared with the conventional laser (e.g. OPO Nd: YAG or TEA-CO 2 ), laser diode is more portable and low cost [13,14]. On the acoustic sensor part, a standard audio microphone without any customization is used.…”
Section: Jinst 15 P04010mentioning
confidence: 99%
“…Selain parameter di atas, pada dasarnya terdapat banyak parameter yang menentukan kinerja dan efisiensi pendingin termoakustik, antara lain: jenis dan tekanan gas, bahan stack, kinerja loudspeaker, konfigurasi resonator, dan lain-lain [5,6,7,8,9,10].…”