2003
DOI: 10.1002/rcm.1141
|View full text |Cite
|
Sign up to set email alerts
|

Surface‐activated no‐discharge atmospheric pressure chemical ionization

Abstract: A new ionization method named surface-activated chemical ionization (SACI) has been realized. In this invention a commercially available atmospheric pressure chemical ionization (APCI) chamber, employed without any corona discharge (no-discharge APCI), has been modified with the insertion of a gold surface, leading to a significant improvement in the ionization efficiency. The ionization of the sample takes place by both gas-phase and surface-activated processes. This new ionization source is able to generate … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
70
0

Year Published

2004
2004
2013
2013

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 41 publications
(71 citation statements)
references
References 29 publications
1
70
0
Order By: Relevance
“…In recent years, other MS techniques have been developed which allow the detection of species directly from solution samples: APCI (atmospheric pressure chemical ionization), 2 APPI (atmospheric pressure photoionization), 3 SACI (surface-activated chemical ionization), 4 and APLI (atmospheric pressure laser ionization). 5 These techniques, and especially the most recently developed SACI and APLI, demonstrate improved sensitivity and reduced chemical noise with respect to ESI, 4,5 and they can be expected to be employed like ESI in the study of metal/ligand equilibria in solution.…”
mentioning
confidence: 99%
“…In recent years, other MS techniques have been developed which allow the detection of species directly from solution samples: APCI (atmospheric pressure chemical ionization), 2 APPI (atmospheric pressure photoionization), 3 SACI (surface-activated chemical ionization), 4 and APLI (atmospheric pressure laser ionization). 5 These techniques, and especially the most recently developed SACI and APLI, demonstrate improved sensitivity and reduced chemical noise with respect to ESI, 4,5 and they can be expected to be employed like ESI in the study of metal/ligand equilibria in solution.…”
mentioning
confidence: 99%
“…This could be the case for peptide ions, which depending on the solution pH, can be in an ionic form. In fact, in a previous investigation (Cristoni et al, 2003b) on SACI performances, a relationship between the…”
Section: A Theoretical Ionization Mechanismmentioning
confidence: 93%
“…Most probably this is because the presence of low electric fields in the ionization chamber and consequently the chemical noise do not extracharge the solvent and therefore the cluster changed molecules and to their reactivity, strongly decrease. This ionization technique has been recently upgraded by Cristoni et al (Cristoni et al, 2003b) to the SACI ionization source that strongly increases the performance mainly in terms of sensitivity when compared to ESI, APCI, and ND-APCI.…”
Section: Surface-activated Chemical Ionization (Saci) Is a New Ionizamentioning
confidence: 99%
“…Recently, a new high sensitivity ionization technique named surfaceactivated chemical ionization (SACI) has been described. 18 A commercially available atmospheric pressure chemical ionization (APCI) chamber, employed without any corona discharge (no-discharge APCI), has been modified with the insertion of a gold surface leading to a significant improvement in the ionization efficiency. The ionization of the sample takes place by both gas-phase and surface-activated processes leading to a high instrumental selectivity and sensitivity.…”
Section: Deoxycortisol In Bloodmentioning
confidence: 99%
“…We postulate that the positively charged surface gives rise to the adsorption and orientation of compounds exhibiting a permanent dipole moment (e.g., H 2 O or CH 3 OH employed in the present LC/MS experiments), thus making protons more available for capture by the analyte neutral molecules and thus increasing the ionization efficiency. 18 Moreover, the application of a low surface potential makes it possible to obtain a better focusing of the ions into the mass analyzer. In the case of 21-DF, the applications of 150 V surface potential gives rise to a 500% increase in signal intensity with respect to that achieved without applying a potential to the floating surface.…”
Section: Rcm Letter To the Editormentioning
confidence: 99%