1953
DOI: 10.1051/jphysrad:019530014012069500
|View full text |Cite
|
Sign up to set email alerts
|

Sur les réactions (dp) et (dn)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

1957
1957
2021
2021

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(7 citation statements)
references
References 5 publications
(11 reference statements)
0
7
0
Order By: Relevance
“…6 The small size was necessary in order to discriminate against gamma rays. A spheroid 4.90 mm by 2.45 mm, on edge to the beam and backed by an aluminum reflector, was used for the N 14 6.36 mm in diameter was used as a detector in the N 16 (d,w)0 16 experiment except for the angular distributions at 1.806, 2.103, and 2.999 Mev where two such cylinders mounted in a copper block were used. The detectors were mounted on Dumont 6292 phototubes whose output pulses were amplified and fed to a hundred-channel analyzer.…”
Section: Experimental Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…6 The small size was necessary in order to discriminate against gamma rays. A spheroid 4.90 mm by 2.45 mm, on edge to the beam and backed by an aluminum reflector, was used for the N 14 6.36 mm in diameter was used as a detector in the N 16 (d,w)0 16 experiment except for the angular distributions at 1.806, 2.103, and 2.999 Mev where two such cylinders mounted in a copper block were used. The detectors were mounted on Dumont 6292 phototubes whose output pulses were amplified and fed to a hundred-channel analyzer.…”
Section: Experimental Methodsmentioning
confidence: 99%
“…The first experiment involving the elastic scattering of energetic particles heavier than a particles was done by Reynolds and Zucker 12 and concerned the scattering of N 14 by N 14 . In spite of the added complexity introduced by the identical nature of the particles the "sharp cutoff" model showed good agreement with the results.…”
Section: Acknowledgmentsmentioning
confidence: 99%
“…The ETV6-NTRK3 gene fusion is typically associated with slow-growing, indolent tumors with a good clinical prognosis and rare instances of distant metastasis [4]. An analysis of 83 patients with SCB revealed a 5-and 10-year overall survival of 87.2% and 76.5%, respectively, and a 5-and 10-year cause-specific survival of 94.4% and 91.4%, respectively [4]. Although rare, recurrences of SCB have been reported, usually occurring after a long diseasefree interval (typically 10-20 years after initial diagnosis) Locally Recurrent Secretory Carcinoma [5,6].…”
Section: Clinical and Functional Significance Of Etv6-ntrk3 Fusionsmentioning
confidence: 99%
“…The dispersion formalism in the single-level approximation relates the elements Ui t v J , to the properties of a single state A of the compound system as follows 4 f Work supported by the U. S. Atomic Energy Commission and by the Graduate School from funds supplied by the Wisconsin Alumni Research Foundation.…”
Section: Cross-section Formulamentioning
confidence: 99%