2019
DOI: 10.1109/jsen.2019.2929505
|View full text |Cite
|
Sign up to set email alerts
|

Suppression of the Bias Error Induced by Magnetic Noise in a Spin-Exchange Relaxation-Free Gyroscope

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 51 publications
(15 citation statements)
references
References 42 publications
0
13
0
Order By: Relevance
“…The extinction ratio can be reduced to 10 -5 by using Glan-Taylor polarizers. To improve detection precision, separate modulations are applied to the probe beam and the pump beam [1,9,11,[19][20][21][22][23]. However, the mechanical error, in an ideal case, is typically no less than 10 -3 rad [13], which is relatively large compared to the angle rotation caused by the weak magnetic field with alkali metal cells and requires calibration.…”
Section: Spin Polarization Of Alkali Metals and Initial Solution To T...mentioning
confidence: 99%
“…The extinction ratio can be reduced to 10 -5 by using Glan-Taylor polarizers. To improve detection precision, separate modulations are applied to the probe beam and the pump beam [1,9,11,[19][20][21][22][23]. However, the mechanical error, in an ideal case, is typically no less than 10 -3 rad [13], which is relatively large compared to the angle rotation caused by the weak magnetic field with alkali metal cells and requires calibration.…”
Section: Spin Polarization Of Alkali Metals and Initial Solution To T...mentioning
confidence: 99%
“…Firstly, in order to evaluate the reduction capability, we first analyzed the magnetic noise of the ferrite magnetic shield under non differential measurement. In different application fields [ 14 , 27 , 32 , 33 , 34 ], the outer diameters of ferrite magnetic shielding are usually 60 mm, 140 mm, and 200 mm. In this paper, the above dimensions of magnetic shielding are used.…”
Section: Noise Reduction Capability Of Differential Measurementmentioning
confidence: 99%
“…The stability of the environmental magnetic field has a direct effect on the measurement performance of sensors. Consequently, passive magnetic shielding and active magnetic compensation are widely used in the aforementioned sectors [ 8 , 9 , 10 ].…”
Section: Introductionmentioning
confidence: 99%
“…The accuracy of the magnetometer limits the accuracy of the active magnetic compensation. Moreover, its high-power consumption requires an external current source [ 9 , 10 ]. The passive magnetic shield uses the characteristics of higher permeability of magnetic material compared with air to cancel the magnetic flux density around the material.…”
Section: Introductionmentioning
confidence: 99%