2013
DOI: 10.1007/s00340-013-5535-x
|View full text |Cite
|
Sign up to set email alerts
|

Suppression of self-pulsing in Tm:YAlO3 lasers via current feedback

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
5
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(7 citation statements)
references
References 15 publications
2
5
0
Order By: Relevance
“…Self-pulsing behavior in a laser may also be explained by nonlinear dynamics with chaotic solutions [8][9][10][11][12], Of particular interest is the NH3 laser [13,14], which can be made to exhibit self-pulsing without any external perturbations. The self-pulsing of our Tm:YA103 laser [4] is remarkably similar to that of chaotic NH3 lasers [8,13]. Additionally, the observation of two distinct dynamical regimes by Razdobreev and Shes takov [7], namely, a stable cw output at low pump power and robust self-pulsing beyond a certain threshold, is consistent with an explanation in terms of nonlinear dynamic systems.…”
Section: Introductionsupporting
confidence: 85%
See 4 more Smart Citations
“…Self-pulsing behavior in a laser may also be explained by nonlinear dynamics with chaotic solutions [8][9][10][11][12], Of particular interest is the NH3 laser [13,14], which can be made to exhibit self-pulsing without any external perturbations. The self-pulsing of our Tm:YA103 laser [4] is remarkably similar to that of chaotic NH3 lasers [8,13]. Additionally, the observation of two distinct dynamical regimes by Razdobreev and Shes takov [7], namely, a stable cw output at low pump power and robust self-pulsing beyond a certain threshold, is consistent with an explanation in terms of nonlinear dynamic systems.…”
Section: Introductionsupporting
confidence: 85%
“…Our measured value of y is much less than that used in the model of Razdobreev and Shestakov [7], To confirm that it would result in a stable cw output, we reproduced their model and used parameters for the laser in our previous work [4], cw output was observed in the model even when various parameters were changed by a factor of 2, including the cross section, cross relaxation, and decay rates, pump rate, and cavity time constant. To further emphasize the robustness of our measurement, we compare the measured pump-probe temporal response with that predicted for y = 0.65, as shown in Fig.…”
Section: -2mentioning
confidence: 67%
See 3 more Smart Citations