Suppression of Baseline Wander Artifact in Magnetocardiogram Using Breathing Sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

3
4

Authors

Journals

citations
Cited by 8 publications
(8 citation statements)
references
References 20 publications
0
8
0
Order By: Relevance
“…A thermistor sensor (TMP102, Texas Instruments, Dallas, TX) with a resolution of 0.06 °C was fixed below the nostrils of the subjects for measuring local changes in temperature during inhalation and exhalation. 22 A microelectromechanical-based three-axis accelerometer (ADXL335, Analog Devices, Norwood, MA) 23 with a measurement range of ±3 g and sensitivity of 300 mV/g was configured to measure vertical movements ( Z axis) of the abdomen by fixing the accelerometer over a belt attached to the waist of subjects. The sensor measured acceleration proportional to body movements that are on pace with respiration or any other voluntary or involuntary motions.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…A thermistor sensor (TMP102, Texas Instruments, Dallas, TX) with a resolution of 0.06 °C was fixed below the nostrils of the subjects for measuring local changes in temperature during inhalation and exhalation. 22 A microelectromechanical-based three-axis accelerometer (ADXL335, Analog Devices, Norwood, MA) 23 with a measurement range of ±3 g and sensitivity of 300 mV/g was configured to measure vertical movements ( Z axis) of the abdomen by fixing the accelerometer over a belt attached to the waist of subjects. The sensor measured acceleration proportional to body movements that are on pace with respiration or any other voluntary or involuntary motions.…”
Section: Methodsmentioning
confidence: 99%
“…Cardiac artifacts in the as-recorded EGG traces were removed by applying the wavelet transform technique. 21,22 The 16-channel data of all the subjects in each measurement condition were subjected to the wavelet decomposition procedure, with typically nine levels of decomposition using the “db 10” wavelet. The approximation coefficient of the wavelet decomposition, which usually contains the lowermost frequency content of any given signal, was used to identify the baseline envelope of the ECG, while the detailed coefficients of wavelet decomposition, which contain cardiac features and other high-frequency noise components in the as-recorded data, were eliminated, as shown in Figure 2a .…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The Arduino Uno microcontroller board was used in this setup, which served two purposes: it allowed one to derive the input power supply since it has an in-built linear voltage regulator, 27 and it also allowed one to measure additional basic functions of the human body, such as temperature near the nostrils for the purpose of correcting baseline wander in the recorded MCG by eliminating the breathing artifact. 28,29…”
Section: Single-supply One-channel Ecg Amplifiermentioning
confidence: 99%
“…Baseline drift and random noise are common degradation problems in signal detection [5, 6]. Several methods based on various theories have been developed to solve these two problems.…”
Section: Introductionmentioning
confidence: 99%