2021
DOI: 10.1109/tpel.2021.3071195
|View full text |Cite
|
Sign up to set email alerts
|

Suppressing DC Current Injection in Transformerless Grid-Connected Inverter Using a Customized Current Sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 20 publications
0
2
0
Order By: Relevance
“…Renewable energies can significantly address the conflict between the growing load demand and environmental protection, ensuring sustainable energy supply [1]. However, its increasing integration brings challenges to Active Distribution Networks (ADNs), such as bi-directional power flow, voltage rise and power fluctuation [2,3].…”
Section: Motivation Of This Researchmentioning
confidence: 99%
See 1 more Smart Citation
“…Renewable energies can significantly address the conflict between the growing load demand and environmental protection, ensuring sustainable energy supply [1]. However, its increasing integration brings challenges to Active Distribution Networks (ADNs), such as bi-directional power flow, voltage rise and power fluctuation [2,3].…”
Section: Motivation Of This Researchmentioning
confidence: 99%
“…As to the optimization of operation issues based on SOP-based flexible resources in ADNs, reference [12] presents a two-stage optimization model for ADNs considering SOP with ES to enhance the economics and security of distribution network operation; reference [13] adopted the maximum DG hosting capacity index to evaluate the benefits of conventional SOP, multi-terminal SOP and SOP with ES, proving that SOP-based flexible resources are capable of increasing the DG penetration of ADNs; reference [14] established an optimization model of the operating efficiency based on four-port SOP with ES; reference [15] proposed the supply restoration strategy in ADNs, replacing ES systems in SOP-based ES with embedded DC microgrids; reference [16] studied the optimization of day-ahead distribution network operation considering the cycle life of the SOP-based ES model. However, the existing SOP-based ES studies have three aspects of research gaps: (1) The previous studies did not consider the effects of SOP-based ES joint model on ADNs planning problem. (2) Most of the prior studies adopted a fixed battery service life of ES systems.…”
Section: Motivation Of This Researchmentioning
confidence: 99%