Superthreshold behavior and threshold estimation of ultrasound-induced lung hemorrhage in pigs: Role of age dependency

Abstract: Age-dependent threshold and superthreshold behavior of ultrasound-induced lung hemorrhage were investigated with 116 2.1 0.3-kg neonate crossbred pigs (4.9 1.6 days old), 103 10 1.1-kg crossbred pigs (39 5 days old), and 104 20 1.2-kg crossbred pigs (58 5 days old). Exposure conditions were: 3.1 MHz, 10-s exposure duration, 1-kHz pulse repetition frequency (PRF), and 1.2-s pulse duration. The in situ (at the pleural surface) peak rarefactional pressure ranged between 2.2 and 10.4 MPa with either eight or nine … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
66
3

Year Published

2006
2006
2020
2020

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 38 publications
(71 citation statements)
references
References 36 publications
2
66
3
Order By: Relevance
“…Fig. 21 shows all of occurrence threshold findings across four species using the same methodology [mouse (Zachary et al, 2001a), rat (Zachary et al, 2001a;O'Brien et al, 2001O'Brien et al, , 2003b, rabbit , and pig (O'Brien et al, 2003a)]. Pre-2000 occurrence threshold findings (Fig.…”
Section: Ultrasound-induced Lung Hemorrhagementioning
confidence: 99%
See 1 more Smart Citation
“…Fig. 21 shows all of occurrence threshold findings across four species using the same methodology [mouse (Zachary et al, 2001a), rat (Zachary et al, 2001a;O'Brien et al, 2001O'Brien et al, , 2003b, rabbit , and pig (O'Brien et al, 2003a)]. Pre-2000 occurrence threshold findings (Fig.…”
Section: Ultrasound-induced Lung Hemorrhagementioning
confidence: 99%
“…Error bars are SEMs. These data, by groupings from left to right, are derived, respectively, from Zachary et al (2001a) and O'Brien et al (2001O'Brien et al ( ,2003aO'Brien et al ( ,b,2006. Summary of lesion occurrence thresholds in terms of p r(in situ) (MPa) (bars; left axis) and MI (lines, right axis) from studies not using our experimental techniques and statistical approach.…”
Section: Fig 19mentioning
confidence: 99%
“…The exposimetry and calibration procedures have been described previously in detail (Frizzell et al 2003;O'Brien et al 2001bO'Brien et al ,2003aO'Brien et al ,2003bO'Brien et al ,2005Zachary et al 2001aZachary et al ,2001b. Ultrasonic exposures were conducted using a focused f/2, 19-mm-diameter, lithium niobate ultrasonic transducer (Valpey Fisher, Hopkinton, MA, USA).…”
Section: Exposimetrymentioning
confidence: 99%
“…However, concerns for its safety continue to be raised and addressed by members of the bioeffects research community (WFUMB 1998;AIUM 2000). These concerns are the result of numerous US-induced lung hemorrhage studies in mice, rats, rabbits, monkeys and pigs at exposure conditions similar to those used for scanning in humans Hartman et al 1990;Penney et al 1993;Raeman et al ,1996Frizzell et al 1994Frizzell et al ,2003Tarental and Canfield 1994;Zachary and O'Brien 1995;Harrison et al 1995;Baggs et al 1996;Holland et al 1996;O'Brien and Zachary 1997;Dalecki et al 1997aDalecki et al ,1997bWFUMB 1998;AIUM 2000;O'Brien et al 2000O'Brien et al ,2001aO'Brien et al , 2001bO'Brien et al ,2003aO'Brien et al ,2003bO'Brien et al ,2005Kramer et al 2001;Zachary et al 2001aZachary et al ,2001b.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation