2006
DOI: 10.2514/1.5781
|View full text |Cite
|
Sign up to set email alerts
|

Supersonic Coaxial Jet Experiment for Computational Fluid Dynamics Code Validation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
29
0

Year Published

2009
2009
2021
2021

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(30 citation statements)
references
References 17 publications
1
29
0
Order By: Relevance
“…A considerable amount of work to perform LES/RANS analyses has also been conducted with other codes [111][112][113][114][115][116][117][118][119][120][121][122][123][124][125][126][127][128][129]. An interesting LES/RANS simulation of a supersonic coaxial jet experiment [130,131] was performed using the VULCAN code [110]. The results are typical of other LES/ RANS simulations such as those cited in the preceding references.…”
Section: Hyper-x and A New Generation Of High-speed Reacting Flomentioning
confidence: 86%
See 2 more Smart Citations
“…A considerable amount of work to perform LES/RANS analyses has also been conducted with other codes [111][112][113][114][115][116][117][118][119][120][121][122][123][124][125][126][127][128][129]. An interesting LES/RANS simulation of a supersonic coaxial jet experiment [130,131] was performed using the VULCAN code [110]. The results are typical of other LES/ RANS simulations such as those cited in the preceding references.…”
Section: Hyper-x and A New Generation Of High-speed Reacting Flomentioning
confidence: 86%
“…Details of the formulation of the method and its application are given by Nik et al [153]. Using the SFMDF methodology, the LES of the coaxial nozzle assembly of Cutler et al [130] was carried out. A schematic of the coaxial nozzle assembly is shown in Fig.…”
Section: Les/filtered Density Function Methods For High-speed Reacmentioning
confidence: 99%
See 1 more Smart Citation
“…The thickness of the central nozzle at the flow outlet is 0.5 mm. This flow has been studied experimentally and numerically with RANS models [53,54]. LES of this flow on a Cartesian grid is also reported [31,55].…”
Section: Coaxial Helium-air Jetmentioning
confidence: 99%
“…Further details concerning the geometry of the rig, and the methodology used for its design, can be found in Ref. 10. The nominal flow conditions for each experiment are given in Tables 1 and 2 along with the cited uncertainties. 10, 11 The thermocouples used to measure the jet temperatures were located in the gas supply lines, and the pressure taps used to measure the operating pressures were positioned as shown in Fig.…”
Section: Geometry Description and Flow Conditionsmentioning
confidence: 99%