Superior Implementation of Accelerated QR Decomposition for Ultrasound Imaging

Abstract: In this work, a novel Minimum Variance Distortion less Response (MVDR) beamformer architecture in which the adaptive weight vector is computed based on modified Column wise Givens Rotation (CGR) is presented. As compared to the conventional MVDR beamformer, Quadrature Rotation Decomposition (QRD)-MVDR is suitable for hardware realizations. To improve the real-time performance requirements of the MVDR Beamformer, a parallel pipe-lined CGR based QRD architecture is employed in the adaptive weight computation sta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
2
2
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(3 citation statements)
references
References 33 publications
0
3
0
Order By: Relevance
“…Each channel output was buffered for FFT segment size (1K), overlapped FFT is implemented with an overlap of 128 sample, and hence there was 896 new samples. The same is depicted in article [12] with a superior implementation technique. Time to process 1K samples were considered as the real time requirement of the MVDR Beamformer, and here it is 51.3µsce.…”
Section: No Of Sample Overlap 128mentioning
confidence: 94%
See 1 more Smart Citation
“…Each channel output was buffered for FFT segment size (1K), overlapped FFT is implemented with an overlap of 128 sample, and hence there was 896 new samples. The same is depicted in article [12] with a superior implementation technique. Time to process 1K samples were considered as the real time requirement of the MVDR Beamformer, and here it is 51.3µsce.…”
Section: No Of Sample Overlap 128mentioning
confidence: 94%
“…In this work we have employed Xilinx™ FFT IP Core [12]. The IP Core was configured as Radix-2, 1024 point, pipelined streaming mode, operates at 200MHz.…”
Section: Data Path Unitsmentioning
confidence: 99%
“…The authors [43] presented the Gabor filter design on the FPGA accelerator for power-efficient and high-performance medical imaging applications. FPGA-based emulation of minimum variance distortionless response beamformer architecture for ultrasound imaging is proposed in [44]. A novel method for the urinary bladder non-invasively volume measuring based on the electrical impedance tomography principles and implemented on FPGA is presented in [25].…”
Section: B Hardware Accelerators For Medical Image Processingmentioning
confidence: 99%