2000
DOI: 10.1590/s0103-50532000000500011
|View full text |Cite
|
Sign up to set email alerts
|

Supercritical fluid extraction and chromatographic analysis (HRGC-FID and HRGC-MS) of Lupinus spp. alkaloids

Abstract: Os extratos de alcalóides de Lupinus spp., obtidos por métodos convencionais (maceração/ sonicação -extração em fase sólida; maceração/sonicação -extração líquido-líquido) e por SFE (extração com fluido supercrítico) usando CO 2 e CO 2 modificado (CO 2 /MeOH, CO 2 /EtOH, CO 2 / i PrOH e CO 2 /H 2 O) foram analisados por CGAR-DIC (cromatografia gasosa de alta resolução com detector de ionização de chama) e CGAR-EM (cromatografia gasosa de alta resolução acoplada à espectrometria de massas). As análises quantita… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0
1

Year Published

2001
2001
2015
2015

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 22 publications
(17 citation statements)
references
References 7 publications
0
16
0
1
Order By: Relevance
“…Water is frequently used as a co-solvent (Bicchi et al 1991;Brachet et al 2000;Park et al 2007). Nonetheless, difficulties related to foam formation and other problems have been reported by some authors (Nossack et al 2000;Pereira et al 2003;Schaeffer et al 1989). The reasons for these problems were explained by the phase equilibria of the CO 2 /H 2 O and CO 2 /H 2 O/alcohol systems .…”
Section: Important Factors In Sfe Processesmentioning
confidence: 92%
“…Water is frequently used as a co-solvent (Bicchi et al 1991;Brachet et al 2000;Park et al 2007). Nonetheless, difficulties related to foam formation and other problems have been reported by some authors (Nossack et al 2000;Pereira et al 2003;Schaeffer et al 1989). The reasons for these problems were explained by the phase equilibria of the CO 2 /H 2 O and CO 2 /H 2 O/alcohol systems .…”
Section: Important Factors In Sfe Processesmentioning
confidence: 92%
“…Helium was used as carrier gas at an average linear velocity of 35 cm · s −1 and a flow rate of 1 mL · min −1 . Alkaloid quantification was performed in full‐scan mode by the internal standard method using caffeine as analytical standard . In the standard solutions the limit of quantification (signal/noise ratio >7) was 0.2 mg kg −1 for sparteine and 0.4 mg kg −1 for all other alkaloids …”
Section: Methodsmentioning
confidence: 99%
“…The extraction was repeated twice and the supernatants decanted while the precipitate was discarded (Oboh et al, 1998). The alkaloids in the sample extract were extracted with dicholorometane and analysed by HRGC-MS (Nossack et al, 2000) performed using a 5973 inert mass selective detector (Agilent technologies USA), coupled to a 6890N GC (Agilent technologies USA). The capillary column used was a 95% methyl, 5% phenylpolysiloxane, HP-5 (Agilent J&W GC Columns) of 30 m length, 0.25 mm i.d., 0,25 µm film thickness.…”
Section: Methodsmentioning
confidence: 99%
“…Lupinus extracts were diluted to 1.0 mL in methanol and 0.3 mL of a caffeine standard solution (1 mg mL -1 ) was added to the sample, which was analysed by GC-MS (Nossack et al, 2000). In the standard solutions the Limit Of Quantification (L.O.Q.…”
Section: Methodsmentioning
confidence: 99%