1977
DOI: 10.1002/pol.1977.130150102
|View full text |Cite
|
Sign up to set email alerts
|

Supercritical fluid chromatography of styrene oligomers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
10
0
1

Year Published

1978
1978
2004
2004

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 41 publications
(11 citation statements)
references
References 7 publications
0
10
0
1
Order By: Relevance
“…Many choices of solvent and column types are available. Polystyrene was analyzed by this technique in 1969 by Jentoft and Gouw (64,65) and later by others (66,67). Using packed capillary columns the resolution of oligomers containing 70 repeat units has been achieved (68).…”
Section: Characterization Of Oligomeric Materialsmentioning
confidence: 99%
“…Many choices of solvent and column types are available. Polystyrene was analyzed by this technique in 1969 by Jentoft and Gouw (64,65) and later by others (66,67). Using packed capillary columns the resolution of oligomers containing 70 repeat units has been achieved (68).…”
Section: Characterization Of Oligomeric Materialsmentioning
confidence: 99%
“…Klesper has pioneered the use of IH_ and 13C_ magnetic resonance to monitor chemical reactions of polymers and has done extensive work on the hydrolysis of isotactic and syndiotactic polyMMA [50][51][52][53][54], on the reactions of diazoalkanes with isotactic and syndiotactic poly(methacrylic acid) [55,56], and on the esterification of poly(methacrylic acids) with alcohols in the presence of carbodiimides [57,58], As an example of the results obtained in these studies, Figure 1 shows the 220 MHz PMR spectra of several syndiotactic methacrylic acid(A)-methyl methacrylate(M) copolymers prepared by the hydrolysis of syndiotactic poly(methyl methacrylate). Separate resonances are evident for the a-methyl protons centered in AAA, (MAA+AAM) , MAM, AMA, (AMM+MMA) and MMM triads.…”
Section: Utilization Of N-add Distributions Measured By Nmrmentioning
confidence: 99%
“…The microbore columns play both the role of sampling and a loop of the sample injector (8). The time required for extract loading is 10 to 60 s. The sample mass deposited on the columns is controlled by the loading period.…”
Section: Directmentioning
confidence: 99%
“…The sample loop (1 µl) is of negligible volume compared to the volume of the extraction vessel (3), 2 ml, plus the associated volumes of the line and hydraulic components. The SFC section comprises PUMP 3, a microbore separation column (4) of 0.8 mm i.d.X50 mm length, a detection system (5,6), a back-pressure regulator (7) and a mass flowmeter (8). The SFC section is connected with the SFE section via VALVE 1.…”
Section: Directmentioning
confidence: 99%
See 1 more Smart Citation