1989
DOI: 10.1080/00387018908053901
|View full text |Cite
|
Sign up to set email alerts
|

1H NMR Spectral Simplification with Achiral and Chiral Lanthanide Shift Reagents. Clenbuterol. Method for Direct Optical Purity Determination

Abstract: The 60 MHz IH NMR spectra of clenbuterol, 1, have been studied in CDC13 solution with the achiral shift reagent, tris(6,6,7,7,8,8,8-hepta-fluoro-2,2-dimethyl-3,6-octanedionato)europiur(IIII), 2, and the 511 Copyright 0 I V X Y by Marcel I k k k e r . IIIL Downloaded by [The University of Manchester Library] at 09:15 20 November 2014 5 12 MARTIN AND ROTHCHILD chiral reagent tris[3-(heptafluoropropylhydroxyn1ethyl-ene)-(+)-canphorato]europiunr(III), 3 . Use of 3 resulted in observable enantiomeric shift differen… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

1993
1993
2010
2010

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 8 publications
(1 citation statement)
references
References 16 publications
0
1
0
Order By: Relevance
“…Using qNMR spectroscopy it is sufficient to find, out of the multitude of NMR signals, a single baseline separated resonance for each component of interest. Besides the application of elaborative pulse sequences and line shape fitting techniques [7] an optimal separation of overlapping resonances can be achieved by changing the kind of solvent [8][9][10][11][12][13][14] or the pH value of the test solution [15][16][17][18][19], by applying different sample concentrations [20][21][22], or by adding auxiliary reagents such as cyclodextrins [23][24][25] or lanthanide shift reagents [23,26]. In some cases, the temperature also affects the signal separation [27,28].…”
Section: Introductionmentioning
confidence: 99%
“…Using qNMR spectroscopy it is sufficient to find, out of the multitude of NMR signals, a single baseline separated resonance for each component of interest. Besides the application of elaborative pulse sequences and line shape fitting techniques [7] an optimal separation of overlapping resonances can be achieved by changing the kind of solvent [8][9][10][11][12][13][14] or the pH value of the test solution [15][16][17][18][19], by applying different sample concentrations [20][21][22], or by adding auxiliary reagents such as cyclodextrins [23][24][25] or lanthanide shift reagents [23,26]. In some cases, the temperature also affects the signal separation [27,28].…”
Section: Introductionmentioning
confidence: 99%