14C Gas Counting: Is There Still a Future?

Abstract: ABSTRACT. Reviewed here are developments in low background proportional counters and chambers used for low-level internal gas counting of '4C. I have studied the influence of counter geometry and the nature of the gas filling on counter characteristics and describe in detail operational characteristics of multi-element proportional chambers. I also discuss detector developments for ultra-low-level gas counting based on a time projection chamber. My observations show that proportional and drift chambers, togeth… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

1992
1992
2019
2019

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 14 publications
(7 citation statements)
references
References 16 publications
0
7
0
Order By: Relevance
“…1951;Houtermans and Oeschger 1955;Drever et al 1957;Nydal 1962;Geyh 1967;Povinec 1972aPovinec , 1992Moúcicki and Zastawny 1977;SrdoË et al 1977). This helped to optimize the detector design as the inner cathode of the detector with proper thickness could be chosen from a material with a minimum radioactive contamination.…”
Section: Multiwire Guard Countersmentioning
confidence: 99%
“…1951;Houtermans and Oeschger 1955;Drever et al 1957;Nydal 1962;Geyh 1967;Povinec 1972aPovinec , 1992Moúcicki and Zastawny 1977;SrdoË et al 1977). This helped to optimize the detector design as the inner cathode of the detector with proper thickness could be chosen from a material with a minimum radioactive contamination.…”
Section: Multiwire Guard Countersmentioning
confidence: 99%
“…Longer counting times improve the statistical resolution of lowcount-rate samples, but the longer the counting time, the greater the probability of electronic shifts in background or efficiency. Approaches to this problem include: 1) development of special counters with extremely high active volumes and/or very low backgrounds (Oeschger & Wahlen 1975;Povinec 1992); 2) the use of isotopic enrichment to concentrate the 14C into normal volume gas proportional counters; and 3) the use of large volume (>10 g of carbon), high-stability, lowbackground liquid scintillation counting (LSC) systems. The high density of carbon and low cosmic-ray profile in a vial of benzene potentially give a high sample-to-background count-rate ratio.…”
Section: Introductionmentioning
confidence: 99%
“…This can be avoided by dividing the sensitive volume into several wall-less counter elements, the so-called multielement counter (Povinec, 1992); however, in practice their operation is rather complex. The sensitivity in GPC can be improved by increasing the size of the counter and by increasing the gas pressure; however, increasing the diameter and/or the pressure would require higher voltages to be applied across the counter.…”
Section: Special Countersmentioning
confidence: 99%