2002
DOI: 10.1088/0954-3899/28/2/305
|View full text |Cite
|
Sign up to set email alerts
|

Sulphur dissociation in nuclear emulsion at 3.7 and 200A GeV

Abstract: In this work, the electromagnetic dissociation (EMD) of sulphur projectile induced by two widely differing energies in nuclear emulsions is investigated. Although the percentages of EMD events of the total numbers of studied interactions are relatively small, i.e. 5.7 and 14.4% for 3.7 and 200A GeV interactions respectively, one could extract some results out of them. The emission of a proton through the 32S(γ, p)31P channel is found to be a dominant process (43.8%) at 200A GeV whereas the single alpha emissio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
9
0

Year Published

2007
2007
2019
2019

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 18 publications
2
9
0
Order By: Relevance
“…Moreover it is evident from the table that the probability of emitting more than one fragment with charge Z>2 is significantly smaller than that of emitting one projectile fragment with charge Z>2. This interpretation has also been supported in [40].…”
Section: Results and Analysissupporting
confidence: 57%
“…Moreover it is evident from the table that the probability of emitting more than one fragment with charge Z>2 is significantly smaller than that of emitting one projectile fragment with charge Z>2. This interpretation has also been supported in [40].…”
Section: Results and Analysissupporting
confidence: 57%
“…They indicate no change in their ionization up to a distance of at least 1cm from the interaction vertex. Their charge can be determined by the δ-ray counting method [16].…”
Section: Methodsmentioning
confidence: 99%
“…1(a, b and c). The corresponding data for different projectiles [7] ( 4 He, 12 C, 16 O, 22 Ne and 28 Si) at ∼ 3.7 A GeV are illustrated in the same figure. From this figure, the width of the MD of Z = 1 (Fig.…”
Section: Dependence Of the Pfs On Projectile Sizementioning
confidence: 99%
“…To obtain a high scanning efficiency, the pellicles were scanned under 100X magnification by doubly scanning along the beam tracks, fast in the forward direction and slow in the backward one. The details about the irradiation and scanning are reported in earlier studies [15,16]. Once an interaction is observed, the incoming track is carefully examined to ensure that it is indeed a beam track.…”
Section: Table (1): the Chemical Composition Of Br-2 Andmentioning
confidence: 99%