2012
DOI: 10.1111/j.1365-2478.2012.01114.x
|View full text |Cite
|
Sign up to set email alerts
|

Suitability of 10 Hz vertical geophones for seismic noise array measurements based on frequency‐wavenumber and extended spatial autocorrelation analyses

Abstract: A B S T R A C TMicrozonation studies using ambient noise measurements constitute a promising way for seismic hazard evaluation in urban areas. Among the existing techniques, seismic noise array measurements have become a valuable tool for estimating Vs profiles and thus, the characteristics of a soil structure. Although methods based on analysis of seismic noise are simpler, cheaper and faster than borehole drilling and down-hole or cross-hole logs to derive shear-wave velocity profiles, array deployment requi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
11
0

Year Published

2014
2014
2021
2021

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 42 publications
0
11
0
Order By: Relevance
“…The small arrays increase the sensitivity to low signal levels and expand the signal frequency band down to 1 Hz, as reported by Rosa‐Cintas et al . (). The distance between two adjacent stations is 200 m, both in the in‐line and cross‐line directions.…”
Section: Surface or Borehole?mentioning
confidence: 97%
“…The small arrays increase the sensitivity to low signal levels and expand the signal frequency band down to 1 Hz, as reported by Rosa‐Cintas et al . (). The distance between two adjacent stations is 200 m, both in the in‐line and cross‐line directions.…”
Section: Surface or Borehole?mentioning
confidence: 97%
“…In the case of Catral, the measures with the Reftek equipment were carried out in 2017. Although the noise characteristics (i.e., amplitude spectra and locations of dominant sources) may be different in each of the time periods, the H/V curves at a particular site are time stable and mainly determined by the soil characteristics [12,51,52]. In this sense, we can observe some amplitude differences among the H/V curves, even when the same recorder is used (e.g., measures taken in Almoradí site with the same Reftek recorder in February and March), but the observed peaks remain approximately at the same frequencies.…”
Section: Field Test With the Three-component Acquisition Systemmentioning
confidence: 99%
“…This area constitutes a well-known place studied in previous works (Rosa-Cintas et al, 2011, 2012a, 2012b.…”
Section: Data Acquisitionmentioning
confidence: 99%
“…The same equipment was recently used by Rosa-Cintas et al (2012b), in a similar way to Galiana-Merino et al (2011), in order to study the suitability of low-cost geophones for taking array measurements of ambient noise and estimating the dispersion curves through the f-k and the ESAC techniques. The comparison of the results obtained by 1Hz-sensors and 10Hz-vertical-geophones arrays in terms of power spectra density…”
mentioning
confidence: 99%
See 1 more Smart Citation