2010
DOI: 10.1016/j.chroma.2010.04.040
|View full text |Cite
|
Sign up to set email alerts
|

Succinyl methacrylate polymerized in porous-layered phases for open-tubular capillary electrochromatography: Comparison with silica hydride monolayered phases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
32
0

Year Published

2010
2010
2016
2016

Publication Types

Select...
7

Relationship

4
3

Authors

Journals

citations
Cited by 20 publications
(33 citation statements)
references
References 44 publications
1
32
0
Order By: Relevance
“…4, which shows EOF at a minimum when ACN content is 40-60%. In fact, the concave shape of the curve could be found in various OT-CEC formats, specifically, in capillaries prepared by direct polymer coating, by stepwise fabrication, or by in situ polymerization [8,28,40,41]. The m eo values determined by using the neutral solute DMSO did not increase with an increasing ratio of ACN in the eluent, acting as if a reversed-phase chromatography solvent was not present at all.…”
Section: The Eof Profiles Upon the Ratio Of Acn Modifiermentioning
confidence: 96%
See 2 more Smart Citations
“…4, which shows EOF at a minimum when ACN content is 40-60%. In fact, the concave shape of the curve could be found in various OT-CEC formats, specifically, in capillaries prepared by direct polymer coating, by stepwise fabrication, or by in situ polymerization [8,28,40,41]. The m eo values determined by using the neutral solute DMSO did not increase with an increasing ratio of ACN in the eluent, acting as if a reversed-phase chromatography solvent was not present at all.…”
Section: The Eof Profiles Upon the Ratio Of Acn Modifiermentioning
confidence: 96%
“…3 illustrate the dependence of electroosmotic mobilities (m eo ) on the pH values of the phosphate buffers for a bare, fused-silica capillary, a g-MAPS silanized capillary, a BMA-CNT capillary, and a BMA-MES capillary. The curve for the BMA-MES capillary, which was prepared using succinate methacrylate (MES) monomer instead of MWNTs, was adapted from a previous study [28]. Among the curves, the g-MAPS and BMA-MES capillaries showed a pattern similar to the bare capillary.…”
Section: Eof Profiles At Buffer Phmentioning
confidence: 99%
See 1 more Smart Citation
“…6 As an extension on the standard thermal polymerization approach, Xu and Sun 23 have also reported the fabrication of a tentacle-type polymermodified OT column by glycidyl methacrylate (GMA) grafted polymerization, for further modification with various functional groups. However, for all of the above work, the biggest challenge when using thermal polymerization is the formation of a uniform polymer layer of desired thickness, with initiator concentration and polymerization time considered as critical factors for the optimization and reproducibility of the immobilization reaction.…”
Section: Introductionmentioning
confidence: 99%
“…Porous layer open tubular (PLOT) columns (see Figure 1) are a type of open tubular column used in a variety of chromatography applications, and although they find some use in liquid chromatography (LC) [1][2][3][4][5][6][7][8][9], capillary electrochromatography [10][11][12][13][14], and micro solid phase extraction (µ-SPE) [15,16], their main area of application is in gas chromatography (GC) [17,18]. Typically, such columns are fabricated through the immobilisation of spherical particles onto the inner wall of the capillary.…”
Section: Introductionmentioning
confidence: 99%