2020
DOI: 10.1002/rcm.8929
|View full text |Cite
|
Sign up to set email alerts
|

Successive and automated stable isotope analysis of CO2, CH4 and N2O paving the way for unmanned aerial vehicle‐based sampling

Abstract: Rationale Measurement of greenhouse gas (GHG) concentrations and isotopic compositions in the atmosphere is a valuable tool for predicting their sources and sinks, and ultimately how they affect Earth's climate. Easy access to unmanned aerial vehicles (UAVs) has opened up new opportunities for remote gas sampling and provides logistical and economic opportunities to improve GHG measurements. Methods This study presents synchronized gas chromatography/isotope ratio mass spectrometry (GC/IRMS) methods for the an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
16
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
3
2
1

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(16 citation statements)
references
References 42 publications
(49 reference statements)
0
16
0
Order By: Relevance
“…Here we present a sampling system coupled to an off-line measurement setup to measure the atmosphere for CO2, CH4, and VOC molar ratios and δ 13 C-value at ambient conditions. Two samplers and a whole-air sample vessel preparation device were developed and evaluated at field conditions, while the measurement setup was evaluated in prior experiments (Leitner et al, 2020). That measurement setup enabled the determination of the mole fraction and stable isotope ratio of carbon of the target compounds detailed herein and can be further applied to investigate the isotope ratios of hydrogen, oxygen and nitrogen in nitrous oxide.…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Here we present a sampling system coupled to an off-line measurement setup to measure the atmosphere for CO2, CH4, and VOC molar ratios and δ 13 C-value at ambient conditions. Two samplers and a whole-air sample vessel preparation device were developed and evaluated at field conditions, while the measurement setup was evaluated in prior experiments (Leitner et al, 2020). That measurement setup enabled the determination of the mole fraction and stable isotope ratio of carbon of the target compounds detailed herein and can be further applied to investigate the isotope ratios of hydrogen, oxygen and nitrogen in nitrous oxide.…”
Section: Discussionmentioning
confidence: 99%
“…CE and reference materials were both sampled in tin cups designed for sampling liquids. The CO2 and CH4 working gas was calibrated against two isotope certified CO2 gas standards (-6.7‰ ± 0.2‰, -39.0‰ ± 0.2‰, ISO-TOP, Messer Austria GmbH) after direct injection to a GC-C-IRMS measurement setup, as presented elsewhere (Leitner et al, 2020). Obtained δ 13 C values ± 1 σ were -4.34‰ ± 0.2‰ (n=17) and -40.3‰ ± 0.2‰ (n=38)…”
Section: Referencing and Calibration Of Stable Carbon Isotope Ratiosmentioning
confidence: 99%
See 3 more Smart Citations