2015
DOI: 10.1016/j.athoracsur.2014.04.064
|View full text |Cite
|
Sign up to set email alerts
|

Successful Bridge Through Transplantation With Berlin Heart Ventricular Assist Device in a Child With Failing Fontan

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0

Year Published

2015
2015
2023
2023

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 41 publications
(28 citation statements)
references
References 8 publications
0
28
0
Order By: Relevance
“…Morales et al [20] reported a successful case of VAD implantation with the Heart Mate II in a 15-year-old Fontan patient with protein-losing enteropathy. Hoganson et al [21] reported successful bridge-toheart transplantation using a Berlin Heart VAD in a child. Niebler et al [22] presented a successful case of using a HeartWare VAD as a bridge to transplantation.…”
Section: Discussionmentioning
confidence: 98%
“…Morales et al [20] reported a successful case of VAD implantation with the Heart Mate II in a 15-year-old Fontan patient with protein-losing enteropathy. Hoganson et al [21] reported successful bridge-toheart transplantation using a Berlin Heart VAD in a child. Niebler et al [22] presented a successful case of using a HeartWare VAD as a bridge to transplantation.…”
Section: Discussionmentioning
confidence: 98%
“…However, for patients with Fontan physiology, the experience with VAD use as BTT is limited. There are several reported cases of patients with Fontan physiology who underwent successful VAD implantation as BTT . A recent review of the EXCOR Investigational Device Exemption study database by Weinstein et al showed 42% mortality for 26 single ventricle patients supported with the Berlin VAD with 42% succesfully weaned to transplant and no patients weaned for recovery.…”
Section: Discussionmentioning
confidence: 99%
“…Several case reports of the use of commercially available implantable left ventricular assist devices have recently been published [41][42][43]. Biomechanical engineers are developing an axial flow impeller device for cavopulmonary assist, a mechanical circulation pulsation device using shape memory alloy fiber to augment inferior vena cava (IVC) to pulmonary artery flow, and there are animal studies of the use of the Jarvik device as a right-sided pump to augment flow from the IVC to the pulmonary artery [44][45][46].…”
Section: Heart Failurementioning
confidence: 98%