2012
DOI: 10.1016/j.jchromb.2011.10.034
|View full text |Cite
|
Sign up to set email alerts
|

Successful and cost-efficient replacement of immunoassays by tandem mass spectrometry for the quantification of immunosuppressants in the clinical laboratory

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

2
13
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(16 citation statements)
references
References 41 publications
2
13
0
Order By: Relevance
“…C min could have been at 0 h post-dose (C 0 ) or at 12 h post-dose (C 12 ) (with twice-daily dosing), or at 24 h post-dose (C 24 ) (with once-daily dosing). Various assays were used for tacrolimus drug measurement, with many studies using the optimal, specific and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) techniques, but a significant number of studies used the relatively less specific but technologically simpler immunoassays [71,72]. Thus, actual reported concentrations and exposures measured using these immunoassays would appear higher than those from studies using LC-MS/MS assays.…”
Section: Pharmacokineticsmentioning
confidence: 99%
“…C min could have been at 0 h post-dose (C 0 ) or at 12 h post-dose (C 12 ) (with twice-daily dosing), or at 24 h post-dose (C 24 ) (with once-daily dosing). Various assays were used for tacrolimus drug measurement, with many studies using the optimal, specific and sensitive liquid chromatography-tandem mass spectrometry (LC-MS/MS) techniques, but a significant number of studies used the relatively less specific but technologically simpler immunoassays [71,72]. Thus, actual reported concentrations and exposures measured using these immunoassays would appear higher than those from studies using LC-MS/MS assays.…”
Section: Pharmacokineticsmentioning
confidence: 99%
“…When clearance is impaired, leading to buildup of drug metabolites, such cross-reactivity can result in a significant over-estimation of the tacrolimus concentration. Additionally, the cost-per-test for immunoassay is higher than for mass spectrometry (MS) assays (4,5). Many of the tacrolimus immunoassays still require manual sample pretreatment before automated analysis by the instrument, while only a selective few may include on-board hemolysis of whole blood specimens to be truly automated.…”
Section: Introductionmentioning
confidence: 99%
“…Therapeutic drug monitoring is integral to the standard of care for a growing number of clinical disciplines, including solid organ transplantation (1), oncology (2, 3), infectious disease management (46), and psychiatry (7). Although these tests provide valuable information that improves patient care by facilitating the maximization of the therapeutic effect and minimization of untoward side effects, the laboratory costs involved in performing these tests— either by MS or immunoassay—are not trivial (8, 9). …”
mentioning