2017
DOI: 10.1007/s10195-017-0466-7
|View full text |Cite
|
Sign up to set email alerts
|

Subtrochanteric femoral shortening osteotomy combined with cementless total hip replacement for Crowe type IV developmental dysplasia: a retrospective study

Abstract: Background Total hip replacement for high dislocation of the hip presents some difficulties, considering patients' young ages, the abnormal hip anatomy and the high rate of complications. In this study, we present our experience in terms of clinical and radiological results in the treatment of Crowe type IV hips with subtrochanteric femoral shortening osteotomy and cementless total hip replacement. Materials and Methods We retrospectively reviewed 15 patients with Crowe type IV hip dysplasia (two bilateral cas… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
33
0
5

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 45 publications
(39 citation statements)
references
References 29 publications
1
33
0
5
Order By: Relevance
“…Non-union of osteotomy may lead to varus angulation, pain, loss of rotational stability, and prosthetic loosening [6,7,23]. The incidence of non-union at the osteotomy site ranges from 0 to 22% [18,29,[31][32][33]. There are multiple contributing factors.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…Non-union of osteotomy may lead to varus angulation, pain, loss of rotational stability, and prosthetic loosening [6,7,23]. The incidence of non-union at the osteotomy site ranges from 0 to 22% [18,29,[31][32][33]. There are multiple contributing factors.…”
Section: Discussionmentioning
confidence: 99%
“…Even cemented fixation of the stem has been used to improve the rotational stability [19,22]. Other factors, which affect union, are the contact area between the proximal and distal segments [18][19][20], bone stock, and vascularity. However, a limited bone contact area is a major disadvantage of transverse osteotomy, which may interfere with the bone healing process [18,19].…”
Section: N a N A N A N A N A N A N A N A N A N A N A N A N A N Amentioning
confidence: 99%
See 2 more Smart Citations
“…Non-union of osteotomy may lead to varus angulation, pain, loss of rotational stability, and prosthetic loosening [6,7,23]. The incidence of non-union at the osteotomy site ranges from 0%-22% [18,29,[31][32][33]. There are multiple contributing factors.…”
Section: Discussionmentioning
confidence: 99%