2009
DOI: 10.1364/ol.34.001261
|View full text |Cite
|
Sign up to set email alerts
|

Subsurface microscopy of integrated circuits with angular spectrum and polarization control

Abstract: We investigate the effect of an annular pupil-plane aperture in confocal imaging while using an NA increasing lens. We show that focal spot shape is highly sensitive to both polarization and angular spectrum of the incoming light. We demonstrate a lateral spatial resolution of 145 nm (lambda(0)/9) in the direction perpendicular to the polarization direction.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

1
7
0

Year Published

2010
2010
2018
2018

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(8 citation statements)
references
References 12 publications
1
7
0
Order By: Relevance
“…Furthermore, the developed electromagnetic model is intended to solve the light propagation from object space to the detector. The stray light originating from the reflections from lens surfaces or chip package are not considered in the image formation process in accordance with the previous studies [3][4][5][6][7][14][15][16].…”
Section: Theorysupporting
confidence: 59%
See 3 more Smart Citations
“…Furthermore, the developed electromagnetic model is intended to solve the light propagation from object space to the detector. The stray light originating from the reflections from lens surfaces or chip package are not considered in the image formation process in accordance with the previous studies [3][4][5][6][7][14][15][16].…”
Section: Theorysupporting
confidence: 59%
“…The derivation steps between Eqs. (4) and (5) are skipped for the sake of brevity; and these details can be found in Ref [16]. In Eqs.…”
Section: Theorymentioning
confidence: 99%
See 2 more Smart Citations
“…The solid immersion lens (SIL), invented by Mansfield and Kino in 1990 [1], has been widely used both in scientific research and industrial application, for example, optical storage [2][3][4][5], photolithography [6][7][8], and microscopy [9][10][11][12][13][14][15][16][17][18]. Due to the higher numerical aperture (NA) of a SIL, the SIL microscopy system provides not only higher spatial resolution and improved light collection efficiency, but also the capability of subsurface imaging with good resolution if the refractive index of the substrate is the same as that of the SIL.…”
Section: Introductionmentioning