2003
DOI: 10.1016/s0901-5027(03)90397-8
|View full text |Cite
|
Sign up to set email alerts
|

Subcutaneous fat layer in different donor regions used for harvesting microvascular soft tissue flaps in slender and adipose patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
8
0

Year Published

2008
2008
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(9 citation statements)
references
References 17 publications
1
8
0
Order By: Relevance
“…This descending order is in accordance with a previous publication that investigated the subcutaneous fat layer of related donor sites and therefore encountered lower values for both forearm flaps and for the scapular and parascapular flaps (Sieg et al, 2003).…”
Section: Discussionsupporting
confidence: 92%
See 2 more Smart Citations
“…This descending order is in accordance with a previous publication that investigated the subcutaneous fat layer of related donor sites and therefore encountered lower values for both forearm flaps and for the scapular and parascapular flaps (Sieg et al, 2003).…”
Section: Discussionsupporting
confidence: 92%
“…This difference can be attributed to differences in the localization of the ultrasound probe when estimating flap thickness, as this was assessed more caudally in a previous study (Sieg et al, 2003).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Another injection fluid depot was at a depth of 3.3 mm, and categorized as located in the shallow hypodermis. Studies evaluating SC skin thickness using ultrasound evaluation have reported a mean abdomen SC skin thickness ranging from 12.2 mm to 40.2 mm according to gender and body mass index,14,15 and a mean anterior thigh SC skin thickness ranging from 7.6 mm to 14.3 mm 14,16. Therefore, a 12.7 mm depth of needle insertion with a skin-fold procedure should ensure that the injection of fluid is made into the SC tissue layer, regardless of the subject’s body characteristics (including body mass index).…”
Section: Discussionmentioning
confidence: 99%
“…12,16 Previous work indicates that the diameter of the superficial compartment keeps constant and is about 1 cm. 1,2,5,6,8,18,19 In our study, the mean overall thickness had been 5.252 cm (±2.065), the thickness of the deep compartment averaged with 3.545 cm (±1. 6), and that of the superficial compartment measured 1.527 cm (± 2.066).…”
Section: Discussionmentioning
confidence: 44%