2014
DOI: 10.1118/1.4888766
|View full text |Cite
|
Sign up to set email alerts
|

SU‐E‐T‐433: Calibration Accuracy in Mailed High‐Resolution 3D Dosimetry Service for SRS/SBRT QA

Abstract: Purpose: SRS/SBRT combines hypofractionation with excellent dose distributions. However, extremely steep gradients across the target along with dose escalation, if not administered accurately, may lead to serious complications, recurrences, or even fatalities. Existing commercial QA products either lack adequate spatial resolution or the 3D aspect. By contrast, the new CrystalBall™ mailed high‐resolution 3D dosimetry service removes the above limitations while reducing the overall workload on medical physics s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 0 publications
0
2
0
Order By: Relevance
“…We used 3D polymer gel dosimeters, CrystalBall TM (MGS Research Inc., Madison, CT), to verify the dose accuracy of SIMT radiosurgery plans. CrystalBall QA system has been reported to have high dosimetric and spatial accuracy in clinical applications in SRS/SBRT (Maryanski et al 2014, Chan 2018. It features a radiosensitive gel sphere of 166 mm in diameter mounted on a special stand to assist reproducible positioning.…”
Section: Independent Verification Of Dlg Using 3d Dosimetrymentioning
confidence: 99%
See 1 more Smart Citation
“…We used 3D polymer gel dosimeters, CrystalBall TM (MGS Research Inc., Madison, CT), to verify the dose accuracy of SIMT radiosurgery plans. CrystalBall QA system has been reported to have high dosimetric and spatial accuracy in clinical applications in SRS/SBRT (Maryanski et al 2014, Chan 2018. It features a radiosensitive gel sphere of 166 mm in diameter mounted on a special stand to assist reproducible positioning.…”
Section: Independent Verification Of Dlg Using 3d Dosimetrymentioning
confidence: 99%
“…A total of six SIMT SRS plans, consisted of 5 targets (2 plans), 6 targets (3 plans), and 15 targets (1 plan), respectively, were delivered and measured using Crys-talBall dosimeters. The irradiated dosimeters were shipped back to MGS Research Inc. where 3D dose was read out by an optical CT with an isotropic voxel size of 0.55 mm (Maryanski et al 2014). A 3D gamma analysis of 3% (of the maximum measured dose) and 2 mm was applied with a cutoff isodose level of 20%.…”
Section: Independent Verification Of Dlg Using 3d Dosimetrymentioning
confidence: 99%