2020
DOI: 10.1002/vjch.2019000132
|View full text |Cite
|
Sign up to set email alerts
|

Studying method of underivatized determination glyphosate, glufosinate and their metabolites in drinking water

Abstract: In Vietnam, glyphosate, one of the most popular herbicides, has recently been prohibited in agriculture due to indiscriminate use and its negative effect on the environment and human's health. Direct analysis and determination glyphosate, glufosinate and their metabolites in environmental samples such as water has get in numerous difficulties due to their simple structure, high polarity and complex formation with different components in the matrices. Therefore, in this research study, we have initially develop… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 12 publications
0
3
0
Order By: Relevance
“…Despite the higher purchase cost, there are some advantages to a high-resolution instrument compared to a low-resolution one. The ability to work at resolutions of up to 70,000 FWHM (Full Width at Half Maximum) for m/z values of 200 [133,134] allows us to monitor fragments up to four or five decimal places (exact masses). This involves the following: (a) Simplifying sample preparation.…”
Section: High-resolution Mass Spectrometrymentioning
confidence: 99%
See 2 more Smart Citations
“…Despite the higher purchase cost, there are some advantages to a high-resolution instrument compared to a low-resolution one. The ability to work at resolutions of up to 70,000 FWHM (Full Width at Half Maximum) for m/z values of 200 [133,134] allows us to monitor fragments up to four or five decimal places (exact masses). This involves the following: (a) Simplifying sample preparation.…”
Section: High-resolution Mass Spectrometrymentioning
confidence: 99%
“…The retention times were about 8 and 6 min for glyphosate and AMPA, respectively (Figure 10). Other works used the Ion Chromatography-Q-Orbitrap system for monitoring glyphosate and AMPA in honey [140] or UHPLC-Q-Orbitrap with a Torus DEA column to analyze glyphosate and AMPA in drinking water [133]. In this last work, the fragment ions monitored for glyphosate were 168.00620 (precursor), 107.02619 (quantification; MS2, collision energy 25 V), and 133.00546 m/z (confirmation; MS2, collision energy 20 V).…”
Section: High-resolution Mass Spectrometrymentioning
confidence: 99%
See 1 more Smart Citation