2018 International Conference on Intelligent Rail Transportation (ICIRT) 2018
DOI: 10.1109/icirt.2018.8641624
|View full text |Cite
|
Sign up to set email alerts
|

Study on the Parameters Affecting the Impedance Extraction Accuracy by Inductive Coupling Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 4 publications
0
5
0
Order By: Relevance
“…Taking into consideration the significance of the online impedance of electrical assets, the extraction of online impedance is now a notable process, thus, a few methods to extract the online impedance will be comprehensively examined with its integrity and limitations highlighted. The extraction methods can be categorized into three types, that is the voltage-current measurement method [8][9][10][11][12][13], capacitive coupling method [14][15][16] and lastly, the inductive coupling method [17][18][19][20][21][22].…”
Section: Section II Literature Review Of Online Impedance Measurementmentioning
confidence: 99%
“…Taking into consideration the significance of the online impedance of electrical assets, the extraction of online impedance is now a notable process, thus, a few methods to extract the online impedance will be comprehensively examined with its integrity and limitations highlighted. The extraction methods can be categorized into three types, that is the voltage-current measurement method [8][9][10][11][12][13], capacitive coupling method [14][15][16] and lastly, the inductive coupling method [17][18][19][20][21][22].…”
Section: Section II Literature Review Of Online Impedance Measurementmentioning
confidence: 99%
“…For this paper, a non-intrusive impedance extraction online method that is based on the inductive coupling approach [4][5][6][7], is used for detecting insulation fault within the stator winding of the induction motor. A known signal generated is input into the induction motor and monitored simultaneously.…”
Section: Introductionmentioning
confidence: 99%
“…Due to the clamp-on type design of the inductive probe, a splitmagnetic core is adopted, and it is prone to magnetic flux leakage, especially when the split gaps of both probes are aligned. If the probe-to-probe coupling is not well-taken care of in the measurement setup, significant errors in the impedance measurement can occur [39]. The comparison shows that the measured in-circuit impedance with 𝑑 = cm deviates significantly due to the strong probe-to-probe coupling.…”
Section: Probe-to-probe Coupling In Tpsmentioning
confidence: 99%
“…Despite the above-mentioned refinements and improvements of the TPS, its major issue is the undesirable probe-to-probe coupling when the two probes are physically placed very close to each other due to space constraints in some practical situations, which can compromise the measurement accuracy [39]. Although a calibration and compensation method has been developed to correct the errors due to the probe-to-probe coupling, it can be a tedious process and havemustrepeated every time if the types of probes and spacing between probes change [40].…”
Section: List Of Tablesmentioning
confidence: 99%
See 1 more Smart Citation