2022
DOI: 10.1016/j.colsurfb.2021.112317
|View full text |Cite
|
Sign up to set email alerts
|

Study on the oriented self-assembly of cuprous oxide micro-nano cubes and its application as a non-enzymatic glucose sensor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 13 publications
(6 citation statements)
references
References 39 publications
0
6
0
Order By: Relevance
“…For the glucose sensor electrode, selectivity was an important factor affecting its accuracy. Considering that the real blood environment usually contains endogenous interfering substances, such as UA, AA, metal ions, and other sugars, their presence may affect the sensitivity of glucose sensors . Therefore, we used 2 mM glucose and 0.1 mM AA, UA, AP, and sodium chloride (NaCl) as interfering substances to conduct an interference test on glucose.…”
Section: Resultsmentioning
confidence: 99%
“…For the glucose sensor electrode, selectivity was an important factor affecting its accuracy. Considering that the real blood environment usually contains endogenous interfering substances, such as UA, AA, metal ions, and other sugars, their presence may affect the sensitivity of glucose sensors . Therefore, we used 2 mM glucose and 0.1 mM AA, UA, AP, and sodium chloride (NaCl) as interfering substances to conduct an interference test on glucose.…”
Section: Resultsmentioning
confidence: 99%
“…Obviously, all of them could be oxidized at the target electrode to generate pronounced oxidation peaks that started at potential ca. 0.40 V. The peak potentials of all the polyhydroxy compounds were in the range of 0.55 to 0.65 V where Cu(II) was oxidized to Cu(III) species [28,34]. The results indicated that Cu(III) sites generated on the surface electrode played key role in the electrochemical detection of these polyhydroxy compounds.…”
Section: Electrochemical Performancesmentioning
confidence: 91%
“…However, they were not suitable for the amperometric detection of CE as the coated materials may fall off during analysis. Since glucose could be detected on cuprous oxide (Cu 2 O)-modified electrodes with high sensitivity [34], it is of high interest to prepare graphene-Cu 2 O hybrid electrode for the measurement of polyhydroxy compounds.…”
Section: Introductionmentioning
confidence: 99%
“…The second factor is selectivity, which refers to the capacity of non-enzymatic glucose sensors to detect only glucose levels without being contaminated by other substances in the sample, such as ascorbic acid, uric acid, and acetaminophen. [38] After it was built, scientists evaluated how well the NiO nanowire array for glucose sensing performed in the presence of potential substances including ascorbic acid, uric acid, and acetaminophen. The findings showed that the NiO nanowire array had a high selectivity for glucose and little influence from the other chemicals tested.…”
Section: Selectivitymentioning
confidence: 99%