The platform will undergo maintenance on Sep 14 at about 7:45 AM EST and will be unavailable for approximately 2 hours.
2011
DOI: 10.5815/ijisa.2011.03.05
|View full text |Cite
|
Sign up to set email alerts
|

Study on The Novel Transient Bus Protection Based on Morphological Top-bottom-operator

Abstract: Abstract-A novel transient component bus protection based on mathematical morphology is presented in this paper, which takes the morphological max top-bottomoperator of current traveling wave to fast distinguish the bus internal fault from the external fault. The method is based on the principle that the high frequency component of transient traveling wave caused by bus external fault will be attenuated by the bus capacitance but the traveling wave caused by bus internal fault changes slightly. Simulation is c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
3
3

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…Generation of reference signal by using a decoupled controlling will enhance transfer behavior of each output variable. A detailed description of crosswise decoupling control by means of stationary state feedback was first developed in [15][16][17][18].…”
Section: ░ 3 Six Phase Statcommentioning
confidence: 99%
“…Generation of reference signal by using a decoupled controlling will enhance transfer behavior of each output variable. A detailed description of crosswise decoupling control by means of stationary state feedback was first developed in [15][16][17][18].…”
Section: ░ 3 Six Phase Statcommentioning
confidence: 99%
“…However, CT is powerful in transforming high‐frequency current signals up to 50 kHz [7]. In other words, protective algorithms based on transient components using current and voltage waves and/or voltage signals are impractical and only and just only, current signal with the sampling frequency not larger than 100 kHz is the best input for algorithms that are based on transient components. Criterion #5: Rule‐based approach : The attempts for transient‐based busbar protection schemes, only represented by simulation results, can be divided into pattern‐recognition based [8, 9, 15] and rule‐based approaches [3–5, 16]. Inherently, the former approach requires massive simulations for training; while, generally, it cannot guarantee 100% accuracy in detecting faults of different conditions and discriminating internal and external faults. In Table 1, according to the aforementioned requirements, the comparison between some busbar protection algorithms that are based on transient components as well as the proposed algorithm has been shown.…”
Section: Introductionmentioning
confidence: 99%
“…Criterion #5: Rule‐based approach : The attempts for transient‐based busbar protection schemes, only represented by simulation results, can be divided into pattern‐recognition based [8, 9, 15] and rule‐based approaches [3–5, 16]. Inherently, the former approach requires massive simulations for training; while, generally, it cannot guarantee 100% accuracy in detecting faults of different conditions and discriminating internal and external faults.…”
Section: Introductionmentioning
confidence: 99%