Abstract:In the EAST experiment, the extent of damages of the divertor is different in toroidal direction. One of the reasons is uneven of heat load of toroidal distribution, which may be caused by geometric errors of the divertor surface. The EAST lower divertor is cooled by 8 toroidal active water-cooling branches, and calorimetric system estimates the heat load and its distribution by measuring the cooling water temperature difference and flow rate. The non-uniformity of the heat load of 8 branches is -3.5% ∼ 4.5%. … Show more
Set email alert for when this publication receives citations?
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.