2014
DOI: 10.5293/ijfms.2014.7.4.142
|View full text |Cite
|
Sign up to set email alerts
|

Study on the Development of Two-Stage Centrifugal Blood Pump for Cardiopulmonary Support System

Abstract: In the cardiopulmonary support system with an ECMO (extracorporeal membrane oxygenation), a higher pump head is demanded for a blood pump. In order to realize a blood pump with higher pump head, higher anti-hemolysis and thrombosis performances, a study on the development of unprecedented multistage blood pump was conducted. In consideration of the application of the blood pump for pediatric patients, a miniature two-stage centrifugal blood pump with the impeller's diameter of 40mm was designed and the perform… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2015
2015
2017
2017

Publication Types

Select...
2
1

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(10 citation statements)
references
References 6 publications
(7 reference statements)
0
10
0
Order By: Relevance
“…The reference rotational speeds of the first prototype which was designed in the previous study [1] and the pump which is improved in the present study are the same and 4000rpm. The first prototype and the improved pump are called Prototype 1 and 2, respectively, in the present study.…”
Section: Pump Performance Testmentioning
confidence: 99%
See 4 more Smart Citations
“…The reference rotational speeds of the first prototype which was designed in the previous study [1] and the pump which is improved in the present study are the same and 4000rpm. The first prototype and the improved pump are called Prototype 1 and 2, respectively, in the present study.…”
Section: Pump Performance Testmentioning
confidence: 99%
“…1 Experimental apparatus for the measurement of pump performance and pressure distribution the design method of the blood pump has not been established yet because the type number of the blood pump is generally low and the internal flow tend to be complex, and moreover the conditions of the occurrence of the hemolysis and the thrombosis are not clear quantitatively as the characteristics of the blood are individually different. Therefore, based on the design method for general industrial centrifugal pumps [4], the authors designed a two-stage centrifugal blood pump (Prototype 1) in the previous study [1], using the knowledge for the suppression of the hemolysis and the thrombosis in single stage blood pumps. The flow rate, the pump head, and the rotational speed at the design point are 3L/min, 500mmHg, and 4200rpm, respectively.…”
Section: Geometrymentioning
confidence: 99%
See 3 more Smart Citations