Study on the characteristic of the grounding fault on the cascaded midpoint side of the hybrid cascaded HVDC system

Abstract: The hybrid cascaded high-voltage direct current (HVDC) system combines the system support capabilities of the modular multilevel converter (MMC) with the capacity of the line-mutated converter’s (LCC’s) advantage of high-power transmission. The HVDC system is among the key elements of a smart grid where artificial intelligence is applied extensively. However, the characteristics of a grounding fault on the cascaded midpoint side of a hybrid cascaded HVDC system remain unclear. This study analyzes fault charact… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 35 publications
0
2
0
Order By: Relevance
“…In the references (Yao et al, 2019;, the realtime post-disaster dispatching strategies for transportable energy storage are proposed in view of the power outages caused by disasters. The efficient dispatching strategies of maintenance crews and restoration crews are developed restore electricity customers after the disasters (Zhang et al, 2020a;Sun et al, 2023). In the reference (Hafiz et al, 2019), load restoration is combined with direct load control and demand response to improve system resilience through the flexibility provided by load.…”
Section: Rzmentioning
confidence: 99%
“…In the references (Yao et al, 2019;, the realtime post-disaster dispatching strategies for transportable energy storage are proposed in view of the power outages caused by disasters. The efficient dispatching strategies of maintenance crews and restoration crews are developed restore electricity customers after the disasters (Zhang et al, 2020a;Sun et al, 2023). In the reference (Hafiz et al, 2019), load restoration is combined with direct load control and demand response to improve system resilience through the flexibility provided by load.…”
Section: Rzmentioning
confidence: 99%
“…In addition, issuing appropriate control instructions to ensure system stability according to operational demands is a problem that cannot be ignored in decision-making. Under abnormal operating conditions, permanent faults occur on the AC or DC side of the system, leading to changes in the topology (Ren et al, 2023). To reduce the impact of faults, decision-making methods are also needed to provide the corresponding combinations of control strategies and solve the allocation problem of transmission power of faulty poles.…”
Section: Introductionmentioning
confidence: 99%