Study on summer thermal performance of a solar ventilated window integrated with thermoelectric air-cooling system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 32 publications
0
4
0
Order By: Relevance
“…Similarly, ref. [39] uses a TE air-cooling system in order to cool the glazing surfaces' airflow in hot climates during summer, this reduces the thermal discomfort of the occupants significantly and reduced the cooling loads of the window as well. The result of the study shows that after a certain number of modules, increasing TEM count on the windows do not contribute to reduction in energy, in fact, in some cases it was also responsible for increase in the consumption of energy and had no considerable impact on energy savings.…”
Section: Integrated Te Systemsmentioning
confidence: 99%
“…Similarly, ref. [39] uses a TE air-cooling system in order to cool the glazing surfaces' airflow in hot climates during summer, this reduces the thermal discomfort of the occupants significantly and reduced the cooling loads of the window as well. The result of the study shows that after a certain number of modules, increasing TEM count on the windows do not contribute to reduction in energy, in fact, in some cases it was also responsible for increase in the consumption of energy and had no considerable impact on energy savings.…”
Section: Integrated Te Systemsmentioning
confidence: 99%
“…The radiative heat transfer coefficients between surfaces and indoors and outdoors are calculated as follows [9] : (9) (10) In Equation ( 7), T sky is the sky temperature given by [9] : (11) Also, T mr in Equation ( 8) is the mean radiant temperature of surfaces surrounding the interior glass surface, which is assumed to be equal to indoor air temperature [15] . 1 and 3 are the total of the long-wave radiative heat exchanges between channel-side surfaces of the interested glass pane and the channel-side surfaces of the other zones.…”
Section: Figure 2 Schematic Of the Ventilated Windowmentioning
confidence: 99%
“…While most of the researchers working on the ventilated window focused on evaluating thermal performance and energy efficiency [7][8][9][10][11][12] , The IAQ and energy consumption analysis has been the subject of limited studies. Gosselin and Chen [6] carried out experimentally validated computational fluid dynamics (CFD) simulations on a proposed dual airflow window to optimize the window design.…”
Section: Introductionmentioning
confidence: 99%
“…The authors reported a maximum COP of 0.45 and a minimum temperature of 17 °C. In a recent study, Khalvati et al [23] analyzed the effects of air temperature attenuation, working interval time, and the number of modules on the performance of a thermoelectric cooling system. Operating the thermoelectric air-cooling system during a short period reduces energy consumption while using it for a longer time might raise it.…”
Section: Introductionmentioning
confidence: 99%