2003
DOI: 10.1016/s0008-8846(02)00974-2
|View full text |Cite
|
Sign up to set email alerts
|

Study on some factors affecting the results in the use of MIP method in concrete research

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
35
0
1

Year Published

2006
2006
2021
2021

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 185 publications
(47 citation statements)
references
References 24 publications
1
35
0
1
Order By: Relevance
“…There has been recently some discussion on the effect that different types of drying have on the MIP measurements [16,17]. In this work samples were vacuum dried for 48 hours and then kept in oven at 50ºC.…”
Section: Cosmentioning
confidence: 99%
“…There has been recently some discussion on the effect that different types of drying have on the MIP measurements [16,17]. In this work samples were vacuum dried for 48 hours and then kept in oven at 50ºC.…”
Section: Cosmentioning
confidence: 99%
“…There are extensive publications reporting the use of MIP (Kumar and Bhattacharjee 2003) and epoxy impregnation techniques (Wong et al 2006), but only a handful of studies (Dullien 1981;Lange et al 1994;Diamond 2000;Nemati 2000;Stroeven et al 2010) have used the metal intrusion/ impregnation technique. The major limitations of the Wood's metal intrusion technique include: (1) the requirement for customized high-pressure chambers and sample holder (Willis et al 1998) to sustain pressure; (2) the difficulty of controlling the pressure, such that customized control units (Lloyd et al 2009) have been needed; (3) the high toxicity of Wood's metal due to its Pb and Cd content (Chen et al 1975;Schubauer-Berigan et al 1993), creating high risk for those involved in the regular handling (grinding and polishing) of samples.…”
Section: Introductionmentioning
confidence: 99%
“…Corrosion of reinforcement in mortars demerits its durability due to the damages caused by the corrosion products in the cement matrix [1,2], being that the use of steel as reinforcement leads to risks of corrosion, the pore solution of mortar can transport aggressive ions, such as chlorides, up to the reinforcement, decreasing the durability [3,4]. In various investigations OPC has been replaced with different types of ash in order to provide durability to mortars, such as: RHA [5,6], cane bagasse ash, fly ash, blast furnace ash, among others, improving mechanical, physical, chemical and electrochemical properties and contributing to diminish the effect of corrosion of reinforcement in various noxious environments [7].…”
Section: Introductionmentioning
confidence: 99%