2016
DOI: 10.17675/2305-6894-2016-5-2-2
|View full text |Cite
|
Sign up to set email alerts
|

Study on corrosion inhibition efficiency of some quinazoline derivatives on stainless steel 304 in hydrochloric acid solutions

Abstract: The effect of the addition of some quinazoline derivatives on the corrosion of stainless steel 304 (SS 304) in hydrochloric acid medium was investigated using electrochemical frequency modulation (EFM), electrochemical impedance spectroscopy (EIS), potentiodynamic polarization, and weight reduction measurements, The inhibition efficiency increases with increasing the inhibitor concentration, but decreases with increasing the temperature. The adsorption of these compounds on the stainless steel 304 surface foll… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
12
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 17 publications
(13 citation statements)
references
References 18 publications
0
12
0
Order By: Relevance
“…Electrochemical studies are used to measure the corrosion resistance of metals and alloys in various media. [12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27] The corrosion resistance of 18K gold in aritificial saliva, in the absenc and presence of Gemer-2 has been evaluated by electrochemical studies such as polarization study and AC impedance spectra.…”
Section: Electrochemical Studiesmentioning
confidence: 99%
“…Electrochemical studies are used to measure the corrosion resistance of metals and alloys in various media. [12][13][14][15][16][17][18][19][20][21][22][23][24][25][26][27] The corrosion resistance of 18K gold in aritificial saliva, in the absenc and presence of Gemer-2 has been evaluated by electrochemical studies such as polarization study and AC impedance spectra.…”
Section: Electrochemical Studiesmentioning
confidence: 99%
“…The AC impedance spectra of SS 316L alloy immersed in Artificial Saliva (AS) in the absence and presence of five tablets obtained from AC impedance spectra are shown in Figures 4, 5. The AC impedance parameters namely charge transfer resistance (R t ) and double layer capacitance (C dl ) derived from Nyquist plots ( Figure 4) and Bode plots ( Figure 5) are also given in this Table 3 [17][18][19][20][21]. In the Nyquist plot the extreme point in the high frequency region corresponds to R s (solution resistance).…”
Section: Analysis Of Ac Impedance Spectramentioning
confidence: 99%
“…If a protective film forms on the metal surface, the linear polarization resistance value (LPR) will increase and corrosion current value (I corr ) decrease [10][11][12][13][14]. Monitoring of LPR [15] is a rapid method of measuring corrosion rate.…”
Section: Potentiodynamic Polarization Studymentioning