2017
DOI: 10.1016/j.jpowsour.2016.11.098
|View full text |Cite
|
Sign up to set email alerts
|

Study of the two-phase dummy load shut-down strategy for proton exchange membrane fuel cells

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 19 publications
(6 citation statements)
references
References 35 publications
0
6
0
Order By: Relevance
“…All the experiments in this work were performed using the Greenlight G60 fuel cell operating platform, and the EIS tests were performed by Gmary Interface 3000 which just as the group works before. 5,18,[24][25][26][27][28] The MEAs used in this work were produced by Wuhan WUT New Energy Co., Ltd. with an active surface area of 50 cm 2 , which is the same as the other work of the group before. 5,[24][25][26][27][28] To ensure that the stack was assembled appropriately, the high-frequency resistance (HFR) was measured by BT3563-01 Impedance Analyzer made by HIOKI, Japan.…”
Section: Setupmentioning
confidence: 99%
“…All the experiments in this work were performed using the Greenlight G60 fuel cell operating platform, and the EIS tests were performed by Gmary Interface 3000 which just as the group works before. 5,18,[24][25][26][27][28] The MEAs used in this work were produced by Wuhan WUT New Energy Co., Ltd. with an active surface area of 50 cm 2 , which is the same as the other work of the group before. 5,[24][25][26][27][28] To ensure that the stack was assembled appropriately, the high-frequency resistance (HFR) was measured by BT3563-01 Impedance Analyzer made by HIOKI, Japan.…”
Section: Setupmentioning
confidence: 99%
“…The result shows that the dummy load can effectively reduce the duration of fuel/air interface, so that the reverse current effect is relieved. Zhang et al [22] propose an extension of Yang's method with a two-phase dummy load strategy. The first main load declined at a certain linear rate, accompanied by the consumption of residual oxygen in the cathode in order to avoid air starvation.…”
Section: Introductionmentioning
confidence: 99%
“…Both anode and cathode compartments are closed simultaneously so that they are no longer supplied with gas when the dummy load is connected. By adding this device, all residual amount of oxygen in the catalyst layer and gas diffusion layer are consumed quickly to limit the fuel/air interface as much as possible as explained in [22].…”
Section: Introductionmentioning
confidence: 99%
“…With the help of the segmented cell technology, the influences of SU/SD condition and the corresponding system strategies have already been investigated by Lin's laboratory , through current density distribution. Lin et al studied the effects of SU/SD condition on the current density distribution.…”
Section: Introductionmentioning
confidence: 99%
“…It led to the carbon corrosion and the performance decrease. Lin et al investigated the dummy load strategy for the shut‐down process. Results showed that after 900 SU/SD cycles, the voltage decline rate under 500 mA cm −2 was 3.33 μV cycle −1 , which confirmed that the dummy load strategy could effectively alleviate the decay of the PEMFC durability.…”
Section: Introductionmentioning
confidence: 99%