2018
DOI: 10.1016/j.physletb.2018.01.079
|View full text |Cite
|
Sign up to set email alerts
|

Study of the process e+e−→K+K− in the center-of-mass energy range 1010–1060 MeV with the CMD-3 detector

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
54
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 44 publications
(56 citation statements)
references
References 17 publications
2
54
0
Order By: Relevance
“…The hadronic part is obtained from a numerical integration over See text for a description of the data used. Middle: comparison between individual e + e − → K + K − cross-section measurements from BABAR [39], CMD-2 [40], CMD-3 [38] and SND [37], and the HVPTools combination. Bottom: local scale factor versus centre-of-mass energy applied to the combined K + K − cross-section uncertainty to account for inconsistency in the individual measurements.…”
Section: Compilation and Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The hadronic part is obtained from a numerical integration over See text for a description of the data used. Middle: comparison between individual e + e − → K + K − cross-section measurements from BABAR [39], CMD-2 [40], CMD-3 [38] and SND [37], and the HVPTools combination. Bottom: local scale factor versus centre-of-mass energy applied to the combined K + K − cross-section uncertainty to account for inconsistency in the individual measurements.…”
Section: Compilation and Resultsmentioning
confidence: 99%
“…Previously, a 5.1% difference between CMD-2 at VEPP-2M and BABAR, with the CMD-2 data being lower, was observed. New results from CMD-3 at VEPP-2000 [38] exhibit the opposite effect: they are 5.5% higher than BABAR (cf. Fig.…”
Section: The K + K − Channelmentioning
confidence: 97%
“…The analysis in Section 16 has shown that the SND, BaBar [76] and the updated [75] CMD-2 data are in fairly good agreement with each other and accommodate easily the HLS context where all other kinds of data are encompassed. Tension has indeed been observed between the CMD-3 data [77,79] and the other samples. This tension has been traced back to the offdiagonal part of the CMD-3 error covariance matrices for both the K + K − and K L K S spectra; this analysis is summarized by Table 2.…”
Section: Figures 2 3 and 4 Together Withmentioning
confidence: 71%
“…Instead, the BS fit performed when discarding the τ data leads to a picture in good correspondence with the RS fit results already commented; indeed, the partial χ 2 's reported in the second data column of Table 3 are similar to those obtained by fitting with the RS variant of the BHLS 2 model. Nevertheless, some tension survives in the 3-pion sector while the dipion 33 The issue between BaBar and CMD-3 charged kaon data has already been noted in [77]. 34 One should note the smaller number of data points considered in the fit procedure for the π + π − π 0 annihilation channel, because of excluding the data points from the φ region.…”
Section: Fit Properties Of the Various Broken Hls Modelsmentioning
confidence: 97%
See 1 more Smart Citation