2006
DOI: 10.1016/j.epsr.2005.12.023
|View full text |Cite
|
Sign up to set email alerts
|

Study of the power system harmonic response in the presence of the Steinmetz circuit

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
13
0
12

Year Published

2007
2007
2020
2020

Publication Types

Select...
4
1
1

Relationship

3
3

Authors

Journals

citations
Cited by 9 publications
(25 citation statements)
references
References 7 publications
0
13
0
12
Order By: Relevance
“…Thus, considering the usual values of the ratios S S /S L and S S /S P [6,9] and the fundamental displacement factors l L and l P , the power system harmonic admittances were studied for the following variable ranges: In Ref. [11], the normalized magnitude of the most critical Y Busk admittances (i.e., jY AAk j N , jY CCk j N , and jY ACk j N ¼ jY CAk j N ) was numerically calculated considering d c ¼ 1, and the series resonance was located as its maximum value.…”
Section: Power System Harmonic Admittancesmentioning
confidence: 99%
“…Thus, considering the usual values of the ratios S S /S L and S S /S P [6,9] and the fundamental displacement factors l L and l P , the power system harmonic admittances were studied for the following variable ranges: In Ref. [11], the normalized magnitude of the most critical Y Busk admittances (i.e., jY AAk j N , jY CCk j N , and jY ACk j N ¼ jY CAk j N ) was numerically calculated considering d c ¼ 1, and the series resonance was located as its maximum value.…”
Section: Power System Harmonic Admittancesmentioning
confidence: 99%
“…In the above conditions, the parallel and series resonance occurring between the Steinmetz circuit capacitor and the system inductors must be located to prevent harmonic problems when the Steinmetz circuit is connected. The parallel resonance occurring between the Steinmetz circuit capacitor and the supply system inductors is widely studied in (Caro et al, 2006;Sainz et al, 2004Sainz et al, , 2005Sainz et al, , 2007. This resonance can increase harmonic voltage distortion in the presence of non-linear loads injecting harmonic currents into the system.…”
mentioning
confidence: 99%
“…The problem is pointed out in (Sainz et al, 2004). In (Caro et al, 2006;Sainz et al, 2005), it is numerically and analytically characterized, respectively. In (Sainz et al, 2005), several curves are fitted numerically from the power system harmonic impedances to predict the resonance at the fifth, seventh and eleventh harmonics only.…”
mentioning
confidence: 99%
See 2 more Smart Citations