2020
DOI: 10.1016/j.measurement.2019.107275
|View full text |Cite
|
Sign up to set email alerts
|

Study of the measurement and mathematical modelling of temperature in turning by means equivalent thermal conductivity

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
8
1
1

Relationship

0
10

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 24 publications
0
5
0
Order By: Relevance
“…To contact the boron-doped diamonds with the developed measurement electronic, two additional boron-structures with an implantation energy of EI = 101 keV, a width of wbs = 200 µm and a length of lbs = 2.16 mm were implanted to enable a complete current flow through the diamond using a doping-level of dlev = 1E 15 -ions/cm 2 . The two specific contacting surfaces AC are characterised by the dimensions 90 µm x 90 µm and were implanted up to the graphitization limit with a higher doping-level of dlev = 2E 16 -ions/cm 2 to achieve a suitable electrical conductivity κ. To avoid short circuits, which would not allow any temperature measurements, a necessary distance between the contacting structures of dC = 1 mm was selected.…”
Section: Ion-implanted Boron-doped Diamondsmentioning
confidence: 99%
“…To contact the boron-doped diamonds with the developed measurement electronic, two additional boron-structures with an implantation energy of EI = 101 keV, a width of wbs = 200 µm and a length of lbs = 2.16 mm were implanted to enable a complete current flow through the diamond using a doping-level of dlev = 1E 15 -ions/cm 2 . The two specific contacting surfaces AC are characterised by the dimensions 90 µm x 90 µm and were implanted up to the graphitization limit with a higher doping-level of dlev = 2E 16 -ions/cm 2 to achieve a suitable electrical conductivity κ. To avoid short circuits, which would not allow any temperature measurements, a necessary distance between the contacting structures of dC = 1 mm was selected.…”
Section: Ion-implanted Boron-doped Diamondsmentioning
confidence: 99%
“…Ng et al [44] positioned an IRT to measure the surface temperature at the back of the chip during turning operations. Similarly, Kus et al [22], Motorcu et al [112], Rezende et al [113] and Kunto glu et al [114] positioned their IRTs to measure the temperature at the tool-chip interface during orthogonal turning operations.…”
Section: Infrared Thermometersmentioning
confidence: 99%
“…The same applies to the Fisher's test, if the F higher value is acceptable and significant [39,[54][55][56]. The assessment was done at a level of α = 0.05 (95% confidence interval) and Fisher's F-test was used to determine the situation in which the composite drilling parameter affects various performance aspects [57][58][59]. The analysis of variance examines the influence of control factors on response effect and allows one to develop a prediction model.…”
Section: Variance Analysis For Cqlmentioning
confidence: 99%