2003
DOI: 10.1016/s0168-9002(03)00346-2
|View full text |Cite
|
Sign up to set email alerts
|

Study of the internal background of CsI(Tℓ) crystal detectors for dark matter search

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
10
0

Year Published

2004
2004
2020
2020

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 36 publications
(11 citation statements)
references
References 11 publications
0
10
0
Order By: Relevance
“…Major internal backgrounds for β-decays in our CsI(Tl) crystals are 137 Cs (Q=1175.6 keV), 134 Cs (Q=2058.7 keV) and 87 Rb (Q=282 keV). The energy spectra from those radioisotopes are flat in our search region, 2 keV to 12 keV, as from Compton-scattered γ rays in the MD events [31,32]. Therefore we expect that the MD energy spectrum is similar to the R e − spectrum in the SD sample.…”
Section: Discussionmentioning
confidence: 71%
See 1 more Smart Citation
“…Major internal backgrounds for β-decays in our CsI(Tl) crystals are 137 Cs (Q=1175.6 keV), 134 Cs (Q=2058.7 keV) and 87 Rb (Q=282 keV). The energy spectra from those radioisotopes are flat in our search region, 2 keV to 12 keV, as from Compton-scattered γ rays in the MD events [31,32]. Therefore we expect that the MD energy spectrum is similar to the R e − spectrum in the SD sample.…”
Section: Discussionmentioning
confidence: 71%
“…Since an axion would give rise to an electron-like signal with a hit in only a single detectormodule, only SD events were selected as axion candidate events. The SD events include surface α events (S α ) and electron recoil events (R e − ) from Compton scattered γ rays and β decays in the crystal bulk [31,32]. The S α events come from decays of radioactive isotopes which contaminate the surfaces of the crystals or the surrounding materials.…”
Section: Discussionmentioning
confidence: 99%
“…[22], this degree of improvement is achievable through the application of additional shielding and well-understood techniques to reduce the dominant internal radiocontaminations of CsI [33] (see also Refs. [34][35][36]). We also include in our analysis an overall systematic uncertainty of ±28% on the overall signal rate, corresponding to uncertainties associated with the cross section, detector efficiency, and overall neutrino flux.…”
Section: Projected Sensitivity To Sterile Neutrinosmentioning
confidence: 99%
“…The dashed black line represents the gain to which all PMTs were matched. The high voltage chosen for each PMT is given inTable 5.1.Before assembly the gain curve of each ET 9102SB was mapped by attaching each PMT to the same crystal and irradiating the setup with a57 Co source, which provides γs with an energy of 122 keV. An Amptek MCA 8000A (Pocket MCA) was used to record the energy spectrum for each PMT operated at several different high voltages.…”
mentioning
confidence: 99%
“…K, 126 I and134, 137 Cs, when grown from appropriate salts[57]. In her PhD thesis[42], Nicole Fields screened a boule slice of CsI[Na] from AMCRYS-H using low-background γ…”
mentioning
confidence: 99%