2001
DOI: 10.1054/arth.2001.28371
|View full text |Cite
|
Sign up to set email alerts
|

Study of retrieved acetabular sockets made from high-dose, cross-linked polyethylene

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
17
0

Year Published

2006
2006
2024
2024

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 32 publications
(18 citation statements)
references
References 3 publications
1
17
0
Order By: Relevance
“…Concurrently, polyethylene researchers at multiple institutions around the world confirmed the finding that elevated doses of radiation crosslinking would reduce wear rates by an order of magnitude during in vitro hip simulator testing [95,103,133]. Clinical researchers in Japan and South Africa reported successful long-term case series initiated in the 1970s in which polyethylene had been exposed to elevated doses of gamma radiation [56,109,111] and silane chemistry [144]. Researchers also found thermal processing after radiation could influence the mechanical properties and oxidative resistance of the polymer [95,103].…”
Section: History and Development Of Hxlpementioning
confidence: 85%
“…Concurrently, polyethylene researchers at multiple institutions around the world confirmed the finding that elevated doses of radiation crosslinking would reduce wear rates by an order of magnitude during in vitro hip simulator testing [95,103,133]. Clinical researchers in Japan and South Africa reported successful long-term case series initiated in the 1970s in which polyethylene had been exposed to elevated doses of gamma radiation [56,109,111] and silane chemistry [144]. Researchers also found thermal processing after radiation could influence the mechanical properties and oxidative resistance of the polymer [95,103].…”
Section: History and Development Of Hxlpementioning
confidence: 85%
“…1). Previous studies report gamma-sterilized PE containing free radicals degrade with substantial oxidation in vivo [10,11,18]. We found the oxidation index of the degraded PE was lower in vivo (retrieved) than in vitro (shelf-aged) (Fig.…”
Section: Discussionmentioning
confidence: 54%
“…The aspect ratio of wear particles in our study was almost equal to that of in vivo wear particles (1.4-1.5) [9], although the ECD was smaller. However, in clinical results [18], the oxidative degradation of 100-Mrad PE was hardly noticeable, possibly as a result of the lower concentration of dissolved oxygen in vivo than that of gaseous oxygen in air (Fig. 5).…”
Section: Discussionmentioning
confidence: 93%