Study of recycled concrete–filled steel tubular columns on the compressive capacity and fire resistance

Abstract: This study presents the analytical formulation of circular steel tubular column with hollow concrete section. This unified analytical formulation can evaluate the axial compression capacity and buckling load of this innovative composite section at normal and high temperature levels, as well as the normal and recycled concrete in a similar fashion. Therefore, the confinement effect on this composite section is uncertain, which in turn leads to complications in axially loaded compression evaluation, because the … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0
1

Year Published

2018
2018
2021
2021

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 26 publications
0
3
0
1
Order By: Relevance
“…Similarly, using NC with recycle aggregate shows that fire resistance of RCFST is extended by about 14% compared to CFHS as the time taken for RCFHS and CFHS to fail are 42 and 49 min, respectively (Wang et al, 2017a). The weakness of Rb-CFHS is during cooling process as the load capacity drops about 17.5% compared to NCFHS, which undergoes 7.6% reduction.…”
Section: Filling Materialsmentioning
confidence: 95%
See 2 more Smart Citations
“…Similarly, using NC with recycle aggregate shows that fire resistance of RCFST is extended by about 14% compared to CFHS as the time taken for RCFHS and CFHS to fail are 42 and 49 min, respectively (Wang et al, 2017a). The weakness of Rb-CFHS is during cooling process as the load capacity drops about 17.5% compared to NCFHS, which undergoes 7.6% reduction.…”
Section: Filling Materialsmentioning
confidence: 95%
“…External fire curve is mainly used for structural member in a façade member to the main member, whereas hydrocarbon fire curve is normally for a situation where petrochemical and plastic form significant part of fire event (Espinos et al, 2011;Yang et al, 2013). ISO 834 has mostly been used across the globe and the standard fire time-temperature curve given in different code is shown in Figure 3 (Espinos et al, 2015b;Shekastehband et al, 2017;Wang et al, 2017a;Siti Nurul Nureda et al, 2017;Neville, 2012).…”
Section: Utilization Of Different Concretesmentioning
confidence: 99%
See 1 more Smart Citation
“…Os poucos trabalhos que abordam as estruturas mistas produzidas com CCAR em situação de incêndio, basicamente, estudam o comportamento de pilares tubulares de aço preenchidos com concreto, como por exemplo, Yang e Hou (2012), Liu et al (2017) e Wang et al (2017), o que evidencia a escassez de pesquisas voltadas às vigas mistas com CCAR, fato este pontuado por Pan et al (2022), sobretudo para as VMPR.…”
Section: Capítulo 1 1 Considerações Iniciaisunclassified