2014
DOI: 10.1016/j.protcy.2014.11.005
|View full text |Cite
|
Sign up to set email alerts
|

Study of Phosphors for White LEDs

Abstract: This paper presents the results of studying four samples of phosphor for white LED manufacture, including the results of spectrum analysis of the phosphors and colorimetric analysis data for light emission values of LEDs containing these phosphors. The paper also presents the results of analyzing colorimetric and brightness characteristics of phosphor-coated LED compound 1 .

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 2 publications
0
1
0
Order By: Relevance
“…To determine CCT we made use of the McCamy formula [34] CCTgoodbreak=5520.33goodbreak−6823normalngoodbreak+3525n2goodbreak−449n3$$ \mathrm{CCT}=5520.33-6823\mathrm{n}+3525{\mathrm{n}}^2-449{\mathrm{n}}^3 $$ where n is given by ngoodbreak=0.25em)(xpgoodbreak−xo0.25em0.25em)(ypgoodbreak−yo0.25em$$ n=\frac{\ \left({\mathrm{x}}_{\mathrm{p}}-{\mathrm{x}}_{\mathrm{o}}\right)\ }{\ \left({\mathrm{y}}_{\mathrm{p}}-{\mathrm{y}}_{\mathrm{o}}\right)\ } $$ …”
Section: Resultsmentioning
confidence: 99%
“…To determine CCT we made use of the McCamy formula [34] CCTgoodbreak=5520.33goodbreak−6823normalngoodbreak+3525n2goodbreak−449n3$$ \mathrm{CCT}=5520.33-6823\mathrm{n}+3525{\mathrm{n}}^2-449{\mathrm{n}}^3 $$ where n is given by ngoodbreak=0.25em)(xpgoodbreak−xo0.25em0.25em)(ypgoodbreak−yo0.25em$$ n=\frac{\ \left({\mathrm{x}}_{\mathrm{p}}-{\mathrm{x}}_{\mathrm{o}}\right)\ }{\ \left({\mathrm{y}}_{\mathrm{p}}-{\mathrm{y}}_{\mathrm{o}}\right)\ } $$ …”
Section: Resultsmentioning
confidence: 99%
“…Due to the spin-orbit coupling, the ground state of Ce 3+ is split into two subband, namely 2 F7/2 and 2 F5/2, with energy difference of 2200 cm −1 . The excited state, 5 D1 configuration is further split into 5 subbands, with upper two band known as eg , 2 D3/5 orbitals and t2g , 2 D5/2, by the crystal field [27], [28]. When the phosphor is excited with blue light, Ce 3+ ions emits green light from 5d( 2 D3/5) to 4f( 2 F5/2) transition and yellow light from transition 5d( 2 D3/5) to 4f( 2 F7/2).…”
Section: Luminescence Propertiesmentioning
confidence: 99%
“…The chromaticity coordinates (colorimetric analysis) of the studied phosphor samples have been determined when the spectrocolorimeter sensor has been directly illuminated by LBE emission. The LBE supply voltage is U = 60 V, the LBE consumption current is I = 10 mA [5].…”
Section: Lbe Production Technology and Colorimetric Analysismentioning
confidence: 99%