Study of Nano-Creep of Unfilled and Filled Cross-Linking Polypropylene

Abstract: Cross-linking is a process in which polymer chains are associated through chemical bonds. Radiation, which penetrated through specimens and reacted with the cross-linking agent, gradually formed cross-linking (3D net), first in the surface layer and then in the total volume, which resulted in considerable changes in specimen behavior. This paper describes the effect of electron beam irradiation on the nanoindentation creep of unfilled and glass fiber filled polypropylene (25%). nanoindentation creep were measu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 10 publications
0
4
0
Order By: Relevance
“…The indentation hardness (H IT ) was calculated as maximum load (F max ) to the projected area of the hardness impression (A p ) and the indentation modulus (E IT ) is calculated from the Plane Strain modulus (E*) using an estimated sample Poisson's ratio according to [12][13][14][15]:…”
Section: Nano-indentation Testmentioning
confidence: 99%
See 1 more Smart Citation
“…The indentation hardness (H IT ) was calculated as maximum load (F max ) to the projected area of the hardness impression (A p ) and the indentation modulus (E IT ) is calculated from the Plane Strain modulus (E*) using an estimated sample Poisson's ratio according to [12][13][14][15]:…”
Section: Nano-indentation Testmentioning
confidence: 99%
“…where h 1 is the indentation depth at time t 1 of reaching the test force (which is kept constant), h 2 is the indentation depth at time t 2 of holding the constant test force [12][13][14][15]. Measurement of all above mentioned properties was performed 10 times to ensure statistical correctness.…”
Section: Nano-indentation Testmentioning
confidence: 99%
“…The dried and cooled residue was weighed again with a precision of five decimal places and compared to the original weight of the portion. The result is stated in percentage as the degree of crosslinking [14]:…”
Section: Gel Contentmentioning
confidence: 99%
“…On the basis of the physicalmechanical properties test, the resulting mixture could be chosen which could meet the requirements of this polymer material when is used at the elevated temperature of this product. [5][6][7][8]…”
Section: Introductionmentioning