Study of Micro/Nano Structuring and Mechanical Properties of KrF Excimer Laser Irradiated Al for Aerospace Industry and Surface Engineering Applications

Abstract: Micro/nano structuring of KrF Excimer laser-irradiated Aluminum (Al) has been correlated with laser-produced structural and mechanical changes. The effect of non-reactive Argon (Ar) and reactive Oxygen (O2) environments on the surface, structural and mechanical characteristics of nano-second pulsed laser-ablated Aluminum (Al) has been revealed. KrF Excimer laser with pulse duration 20 ns, central wavelength of 248 nm and repetition rate of was utilized for this purpose. Exposure of targets has been carried out… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(3 citation statements)
references
References 65 publications
0
3
0
Order By: Relevance
“…SEM analysis is utilized for the investigation of variation in surface morphology, average ablation depth (δ) and ablated diameter (D) of ablated region for varying number of pulses, i.e., 500, 1000, 1500, and 2000. ImageJ software is used for the evaluation of δ and D, whereas the ablated volume ( V ) is calculated by using the following formula [ 24 ]: …”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…SEM analysis is utilized for the investigation of variation in surface morphology, average ablation depth (δ) and ablated diameter (D) of ablated region for varying number of pulses, i.e., 500, 1000, 1500, and 2000. ImageJ software is used for the evaluation of δ and D, whereas the ablated volume ( V ) is calculated by using the following formula [ 24 ]: …”
Section: Resultsmentioning
confidence: 99%
“…This variation in values of δ, D and V is related to the variation in energy absorption with the variation in number of pulses. The increase in ablated volume and depth might be related to the fact that less or no thermal conduction and less plasma expansion is taking place, causing the target surface to absorb maximum part of energy, which in turn causes an increase in values of δ, D and V [ 24 ]. With the increase in number of pulses to 1500, the conduction of heat on the irradiated Cd surface takes place, causing the reduction in energy absorption for target ablation.…”
Section: Resultsmentioning
confidence: 99%
“…General surface properties, including wetting, are very important in a multitude of fields, including aerospace [ 45 ], maritime [ 46 ], heavy industry [ 47 ], and medicine [ 48 ]. At the same time, while various pilot-level tests are presented in the literature, there are still a multitude of challenges separating academic achievements from widespread use.…”
Section: Discussionmentioning