2021
DOI: 10.1557/s43579-021-00068-2
|View full text |Cite
|
Sign up to set email alerts
|

Study of low temperature solution-processed amorphous KNN thin films using PFM

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(7 citation statements)
references
References 30 publications
0
7
0
Order By: Relevance
“…[ 35,36 ] However, at higher applied voltage levels, the relationship can potentially depart from strict linearity due to electrostatic and mechanical deformation effects. To contrast the present work from earlier PFM measurements, [ 37 ] we note that we have previously distinguished nonlinear effects arising from a nonlinear response of the composite film‐tip system at high biases and identified PFM measurements with the first harmonic amplitude of displacement ( FHA normald Tip displacement Bias ) rather than d 33 per se as the tip's electrostatic interaction with the sample plays a strong enough role to make PFM a difficult method for d 33 measurement. [ 16,38 ]…”
Section: Discussionmentioning
confidence: 80%
See 3 more Smart Citations
“…[ 35,36 ] However, at higher applied voltage levels, the relationship can potentially depart from strict linearity due to electrostatic and mechanical deformation effects. To contrast the present work from earlier PFM measurements, [ 37 ] we note that we have previously distinguished nonlinear effects arising from a nonlinear response of the composite film‐tip system at high biases and identified PFM measurements with the first harmonic amplitude of displacement ( FHA normald Tip displacement Bias ) rather than d 33 per se as the tip's electrostatic interaction with the sample plays a strong enough role to make PFM a difficult method for d 33 measurement. [ 16,38 ]…”
Section: Discussionmentioning
confidence: 80%
“…To contrast the present work from earlier PFM measurements, [37] we note that we have previously distinguished nonlinear effects arising from a nonlinear response of the composite film-tip system at high biases and identified PFM measurements with the first harmonic amplitude of displacement (FHA d ≡ Tip displacement…”
Section: Discussionmentioning
confidence: 81%
See 2 more Smart Citations
“…In this regard, their inorganic counterparts such as aluminium nitride (AlN), zinc oxide (ZnO), lead zirconate titanate (PZT), potassium sodium niobate (KNN) etc. offer better solution [25][26][27][28]. Amongst these, PZT is not recommended due to presence of toxic lead element (over 60 wt.%) [29].…”
Section: Introductionmentioning
confidence: 99%