2021
DOI: 10.15587/2706-5448.2021.225328
|View full text |Cite
|
Sign up to set email alerts
|

Study of dust collection effectiveness in cyclonic-vortex action apparatus

Abstract: The object of research is the efficiency of dust collection of fine dust in an apparatus with an intense turbulent mode of phase interaction. One of the most problematic areas of the existing dust and gas cleaning equipment is the low efficiency of collecting fine dust. Effective cleaning of exhaust gases from dust involves the use of multi-stage cleaning systems, including wet and dry dust cleaning devices, which entails high capital and operating costs. These disadvantages are eliminated in the developed des… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(3 citation statements)
references
References 15 publications
0
3
0
Order By: Relevance
“…Granite PM has the highest specific gravity as compared to the other investigated materials. The obtained overall air treatment efficiency was 9-11 % higher than the results reported for a dust collector of a cyclonic-vortex dry-type plant at an optimal velocity of 5 m s -1 [14]. In a previous research study [39] the optimal velocity for a conventional cyclone design with multi inlet guide channels is reported to be 8.8 m s -1 .…”
Section: Figure 4 Overall Air Treatment Efficiency In the One-level 8-channel Cyclone-separator Mock-up For Different Pm With Particle Simentioning
confidence: 61%
See 2 more Smart Citations
“…Granite PM has the highest specific gravity as compared to the other investigated materials. The obtained overall air treatment efficiency was 9-11 % higher than the results reported for a dust collector of a cyclonic-vortex dry-type plant at an optimal velocity of 5 m s -1 [14]. In a previous research study [39] the optimal velocity for a conventional cyclone design with multi inlet guide channels is reported to be 8.8 m s -1 .…”
Section: Figure 4 Overall Air Treatment Efficiency In the One-level 8-channel Cyclone-separator Mock-up For Different Pm With Particle Simentioning
confidence: 61%
“…Complex pollution of dusted gases requires the use of multistage treatment systems, including dry and wet cleaning devices, which increases capital and operating costs [17,18]. Apparatus for complex purification of off gases operates in the regime of developed turbulence and is a promising tool for solving this problem [13,14].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation