Study of cryogenic photomultiplier tubes for the future two-phase cryogenic avalanche detector

Abstract: A: We report the results of a characterization study of several types of cryogenic photomultipliers manufactured by Hamamatsu Photonics and intended for operation in liquid Ar conditions, namely: compact 2-inch R6041-506MOD tubes, 3-inch R11065-10 and R11065-MOD tubes for operation in liquid Ar and 3-inch R11410-20 tubes originally designed for operation in liquid Xe. These types of PMT are proposed for installation into the future two-phase cryogenic avalanche detector that is developed in the Laboratory of C… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0
3

Year Published

2017
2017
2020
2020

Publication Types

Select...
6

Relationship

5
1

Authors

Journals

citations
Cited by 9 publications
(11 citation statements)
references
References 18 publications
(22 reference statements)
0
8
0
3
Order By: Relevance
“…The N 2 content was below 1 ppm (with the measurement accuracy of 1 ppm); it was constantly monitored before and after each cryogenic run using gas analyzer "SVET" [48], which employed emissionspectrum-measurement technique. The detector was operated in a two-phase mode in the equilibrium state, at a saturated vapor pressure of 1.000±0.005 atm and at a temperature of 87.3 K. The EL gap, formed by the liquid surface and a THGEM plate (THGEM1 in the figure), was viewed by four compact 2inch PMTs R6041-506MOD [49,50], located on the perimeter of the gap. The PMTs were electrically insulated from the gap by an acrylic box.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%
“…The N 2 content was below 1 ppm (with the measurement accuracy of 1 ppm); it was constantly monitored before and after each cryogenic run using gas analyzer "SVET" [48], which employed emissionspectrum-measurement technique. The detector was operated in a two-phase mode in the equilibrium state, at a saturated vapor pressure of 1.000±0.005 atm and at a temperature of 87.3 K. The EL gap, formed by the liquid surface and a THGEM plate (THGEM1 in the figure), was viewed by four compact 2inch PMTs R6041-506MOD [49,50], located on the perimeter of the gap. The PMTs were electrically insulated from the gap by an acrylic box.…”
Section: Experimental Setup and Proceduresmentioning
confidence: 99%
“…1 shows the experimental setup for the present measurement session, of 2019; it was modified compared to the previous measurement session, of 2018, described in [1] (see below). The setup comprised a two-phase TPC with EL gap, filled with liquid Ar and operated in the two-phase mode at a saturated vapor pressure of 1.0 atm and temperature of 87.3 K. The EL gap, formed by the liquid surface and THGEM1 electrode, was viewed by four compact PMTs R6041-506MOD [6], located on the perimeter of the gap. The PMTs were electrically insulated from the gap by an acrylic box.…”
Section: Introductionmentioning
confidence: 99%
“…В Видно, что ионизационный выход зависит от энергии нетривиальным образом: ионизационный выход сначала уменьшается, а затем растет с энергией, проходя через минимум. Следует отметить, что подобная энергетическая зависимость для электронов отдачи в жидком Ar наблюдалась ранее [14] (рис. 7).…”
Section: результаты экспериментаunclassified
“…Ионизационные выходы электронов отдачи в жидком Ar при электрическом поле 2,4 кВ/см как функция энергии. Данные взяты из Sangiorgio et al [29] (при 0,27, 2,8 и 5,9 кэВ), из Bondar et al [14] (при 35 кэВ), из Scallettar et al [30] (при 364 кэВ) и из Shibamura et al [31] (при 976 кэВ) и аппроксимированы сплайн-кривой (рисунок приводится по: [14]) зависимость для ядер отдачи в жидком Xe является монотонной в диапазоне от 1 до 300 keVnr [32].…”
Section: результаты экспериментаunclassified