2005
DOI: 10.1016/j.nucengdes.2005.02.010
|View full text |Cite
|
Sign up to set email alerts
|

Study of countercurrent flow limitation in a horizontal pipe connected to an inclined one

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

3
24
0
11

Year Published

2010
2010
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 62 publications
(43 citation statements)
references
References 5 publications
3
24
0
11
Order By: Relevance
“…This kind of hysteresis in CCFL characteristics has also been observed in countercurrent flows in a vertical pipe 14) of D ¼ 0:032 m and a simulated hot leg 8) of D ¼ 0:054 m. However, flow patterns and the mechanism of the hysteresis have not been well understood yet.…”
Section: Outline Of Air-water Testsmentioning
confidence: 56%
See 1 more Smart Citation
“…This kind of hysteresis in CCFL characteristics has also been observed in countercurrent flows in a vertical pipe 14) of D ¼ 0:032 m and a simulated hot leg 8) of D ¼ 0:054 m. However, flow patterns and the mechanism of the hysteresis have not been well understood yet.…”
Section: Outline Of Air-water Testsmentioning
confidence: 56%
“…It is, therefore, necessary to understand the detailed characteristics of a countercurrent flow in the hot leg for developing a reliable model for predicting the flow. Although a number of experiments have been carried out on the countercurrent flow limitation, CCFL, in the hot leg, [3][4][5][6][7][8][9][10] two-phase flow patterns in the hot leg geometry have not been observed. Detailed knowledge on flow patterns in the inclined pipe and elbow in the hot leg under countercurrent flow conditions, therefore, has not been reported.…”
Section: Introductionmentioning
confidence: 99%
“…A number of experiments have been carried out on the countercurrent flow limitation (CCFL) in the hot leg. [3][4][5][6][7][8] On the other hand, reported observations of flow patterns are limited and have been made only for horizontal pipes 9) or under cocurrent flow conditions. 10) Detailed knowledge on flow patterns in the inclined pipe and the elbow in the hot leg under countercurrent flow conditions has not been reported.…”
Section: Introductionmentioning
confidence: 99%
“…Navaro [16] studied countercurrent flow limitation in a horizontal pipe connected to an inclined one. He investigated the effect of various geometrical parameters of the test section on the onset of flooding, on the partial delivery of water and on the zero liquid penetration.…”
Section: Introductionmentioning
confidence: 99%