2017
DOI: 10.1016/j.cej.2016.07.099
|View full text |Cite
|
Sign up to set email alerts
|

Study of butyraldehyde degradation and by-products formation by using a surface plasma discharge in pilot scale: Process modeling and simulation of relative humidity effect

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
14
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 27 publications
(15 citation statements)
references
References 23 publications
1
14
0
Order By: Relevance
“…There was an obvious broad absorption band in the range of 200–800 nm, indicating the WS 2 had good light absorption capacity, which would be beneficial to photocatalysis (Figure a). According to Tauc formula(αhv)2=C'(hv-Eg) , the extrapolated band gap of WS 2 was about 1.5 eV (Figure b), which was consistent with the band gap of the single‐layer WS 2 nanosheets reported in the literature . Figure c showed photoluminescence spectrum of WS 2 nanosheets, and the maximum emission wavelength was 405 nm using 260 nm as the excitation light with broadening peak shape.…”
Section: Resultssupporting
confidence: 85%
“…There was an obvious broad absorption band in the range of 200–800 nm, indicating the WS 2 had good light absorption capacity, which would be beneficial to photocatalysis (Figure a). According to Tauc formula(αhv)2=C'(hv-Eg) , the extrapolated band gap of WS 2 was about 1.5 eV (Figure b), which was consistent with the band gap of the single‐layer WS 2 nanosheets reported in the literature . Figure c showed photoluminescence spectrum of WS 2 nanosheets, and the maximum emission wavelength was 405 nm using 260 nm as the excitation light with broadening peak shape.…”
Section: Resultssupporting
confidence: 85%
“…DBD plasma was created by applying high voltage power via a signal generator (BFi OPTILAS (SRS) reference DS 335/1). The applied voltage, as a sinusoidal waveform of 10V, was then amplified to 30 kV by an amplifier (TREK 30A/40) [20,[22][23][24][25]. This amplifier is connected to the reactor outer/inner electrodes, in a copper and Al grid form for the outer and inner electrodes, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…The polluted air flow was generated continuously by means of a syringe pump system (Kd Scientific Model 100, USA) in order to obtain a stable VOC concentration during the experiment (from 5 to 20 mg.m -3 ). To create a VOCs/air mixture, two similar injection systems are used for each pollutant [29][30][31]. A static mixer at upstream ensures a proper mixing of air .…”
Section: Polluted-contaminated Air Generationmentioning
confidence: 99%